WEBVTT 540fd2ae-971d-4698-9b97-88a56f217c4d-0 00:00:02.920 --> 00:00:07.009 Good afternoon, I am Chrissi Guth with CBP's Office of Trade 540fd2ae-971d-4698-9b97-88a56f217c4d-1 00:00:07.009 --> 00:00:07.680 Relations. e627b7a7-7ce6-43d8-9c59-c19cefe374f7-0 00:00:08.160 --> 00:00:12.880 Today's webinar is on Industrial Controls Apparatus Part 2. 020897ab-547e-45b1-a7e0-9c5f1ba9c1e4-0 00:00:13.640 --> 00:00:16.315 Please be mindful that you will be on mute during the 020897ab-547e-45b1-a7e0-9c5f1ba9c1e4-1 00:00:16.315 --> 00:00:16.960 presentation. 1d26238f-3ee2-4557-bb65-4f05e056c21e-0 00:00:17.480 --> 00:00:20.677 Therefore, we ask that you submit your any questions you 1d26238f-3ee2-4557-bb65-4f05e056c21e-1 00:00:20.677 --> 00:00:22.080 have in the chat feature. af0fa0dc-f0e3-4876-bc13-bc2c0bb607ba-0 00:00:22.920 --> 00:00:26.766 If you plan to request the optional CCS or CES credits af0fa0dc-f0e3-4876-bc13-bc2c0bb607ba-1 00:00:26.766 --> 00:00:31.241 through the NCBFAA Educational Institute, please check the chat af0fa0dc-f0e3-4876-bc13-bc2c0bb607ba-2 00:00:31.241 --> 00:00:33.200 box for the completion code. a0c45669-e4c2-410a-b8a6-3fd3e295ae10-0 00:00:33.600 --> 00:00:36.440 It will be provided several times throughout the webinar. 4ea2cb75-bda8-424c-8ce9-d51409bd6b9c-0 00:00:37.000 --> 00:00:40.888 Now I would like to pass it over to national import Specialist 4ea2cb75-bda8-424c-8ce9-d51409bd6b9c-1 00:00:40.888 --> 00:00:42.000 Carl Moosebrugger. 90f9a9da-f0b8-44f1-84ab-f5300ae1164b-0 00:00:45.560 --> 00:00:46.440 Thank you Chrissi. 68a96f27-ca4c-4acf-ab5d-7edebac8f190-0 00:00:46.640 --> 00:00:47.760 Welcome everyone. a700bed2-9abb-4f5e-a614-e0a751136775-0 00:00:48.120 --> 00:00:49.880 My name is Carl Moosebrugger. c91a57dd-b603-409f-bbe2-6d1af5b93d05-0 00:00:49.880 --> 00:00:54.341 I'm a national import specialist with US Customs and Border c91a57dd-b603-409f-bbe2-6d1af5b93d05-1 00:00:54.341 --> 00:00:55.160 Protection. cca331c1-c858-48cd-a0c3-cb7d3dfb3d5e-0 00:00:55.440 --> 00:00:57.600 I'm also known as NIS 220. ac648978-b9f4-4a8c-ac09-8581316e52c8-0 00:00:57.600 --> 00:01:02.496 I'm one of the four electronics branch NIS's, and I just wanted ac648978-b9f4-4a8c-ac09-8581316e52c8-1 00:01:02.496 --> 00:01:07.470 to thank you for taking the time out of your schedules to attend ac648978-b9f4-4a8c-ac09-8581316e52c8-2 00:01:07.470 --> 00:01:11.831 today's webinar presentation on industrial manufacturing ac648978-b9f4-4a8c-ac09-8581316e52c8-3 00:01:11.831 --> 00:01:12.520 controls. 389953b0-1cfd-494c-9243-73cfa31fe1c0-0 00:01:14.880 --> 00:01:18.586 Before we get started, we're required to go over some general 389953b0-1cfd-494c-9243-73cfa31fe1c0-1 00:01:18.586 --> 00:01:22.352 housekeeping slides, which by now, if you've ever participated 389953b0-1cfd-494c-9243-73cfa31fe1c0-2 00:01:22.352 --> 00:01:25.759 in a customs webinar, it should be very familiar to you. aa77d409-ac84-416b-890d-8d821b0568ed-0 00:01:27.080 --> 00:01:29.520 Here are our current mission statements. 573d6b69-9a03-4220-afc4-3962d4571214-0 00:01:31.960 --> 00:01:35.725 A new webinar requirement this year is that we must mention CBP's 573d6b69-9a03-4220-afc4-3962d4571214-1 00:01:35.725 --> 00:01:37.160 Green Trade Strategy. 48412b1b-5a77-4365-bd4f-75c8dc60e74b-0 00:01:38.280 --> 00:01:41.865 While today's webinar will not cover the Green Trade strategy, 48412b1b-5a77-4365-bd4f-75c8dc60e74b-1 00:01:41.865 --> 00:01:45.450 I've included the web address here so that you can familiarize 48412b1b-5a77-4365-bd4f-75c8dc60e74b-2 00:01:45.450 --> 00:01:47.840 yourself with this topic at your leisure. 5c0c4e61-9502-4dba-a94c-c5e0d24ad7b2-0 00:01:51.840 --> 00:01:55.450 CBP provides these webinars to the trade community to promote 5c0c4e61-9502-4dba-a94c-c5e0d24ad7b2-1 00:01:55.450 --> 00:01:58.886 an understanding of the laws and regulations pertaining to 5c0c4e61-9502-4dba-a94c-c5e0d24ad7b2-2 00:01:58.886 --> 00:02:02.496 various subjects as instruction and tariff classification and 5c0c4e61-9502-4dba-a94c-c5e0d24ad7b2-3 00:02:02.496 --> 00:02:04.360 other compliance related topics. c08075a2-0108-47eb-bdb1-9179661f6e8b-0 00:02:05.480 --> 00:02:08.891 Our intent for this webinar is to discuss the tariff c08075a2-0108-47eb-bdb1-9179661f6e8b-1 00:02:08.891 --> 00:02:12.753 classification of electrical machines and apparatus used in c08075a2-0108-47eb-bdb1-9179661f6e8b-2 00:02:12.753 --> 00:02:16.680 manufacturing processes and industrial control applications. 6ce28335-6101-4e7e-b45a-e5ba702306ab-0 00:02:18.360 --> 00:02:22.907 This is a complex topic and six and since technology has the 6ce28335-6101-4e7e-b45a-e5ba702306ab-1 00:02:22.907 --> 00:02:27.827 tendency to evolve, this webinar should be used as a training aid 6ce28335-6101-4e7e-b45a-e5ba702306ab-2 00:02:27.827 --> 00:02:28.200 only. e393dd16-08fd-4f8f-ae7e-a2f3ed7b54d5-0 00:02:31.400 --> 00:02:34.886 When CBP issues a ruling, it does so based on a certain set e393dd16-08fd-4f8f-ae7e-a2f3ed7b54d5-1 00:02:34.886 --> 00:02:36.920 of facts for that particular item. 59500ba8-ee71-439b-9db3-ffadd654cfb1-0 00:02:37.680 --> 00:02:41.273 Rulings can be a great tool for classifying merchandise, and 59500ba8-ee71-439b-9db3-ffadd654cfb1-1 00:02:41.273 --> 00:02:44.808 searching cross for similar items can be useful and get you 59500ba8-ee71-439b-9db3-ffadd654cfb1-2 00:02:44.808 --> 00:02:45.279 started. 466e7ba6-c4b9-470c-b73e-d9c508582d1f-0 00:02:46.840 --> 00:02:51.221 But each ruling is based on a specific set of facts for that 466e7ba6-c4b9-470c-b73e-d9c508582d1f-1 00:02:51.221 --> 00:02:55.027 specific item, so the circumstances and analysis may 466e7ba6-c4b9-470c-b73e-d9c508582d1f-2 00:02:55.027 --> 00:02:59.409 not relate to other products, regardless of how similar they 466e7ba6-c4b9-470c-b73e-d9c508582d1f-3 00:02:59.409 --> 00:02:59.840 sound. 2d4f2102-3baa-404e-8732-727e56915abe-0 00:03:04.680 --> 00:03:08.024 And we should point out that the reliance solely on the general 2d4f2102-3baa-404e-8732-727e56915abe-1 00:03:08.024 --> 00:03:11.003 information contained in a webinar may not be considered 2d4f2102-3baa-404e-8732-727e56915abe-2 00:03:11.003 --> 00:03:11.840 reasonable care. 4bdbfbb4-83d2-4c9c-b9ea-a2c4d3c4e8b4-0 00:03:12.480 --> 00:03:16.556 This webinar is not intended to replace the need for an importer 4bdbfbb4-83d2-4c9c-b9ea-a2c4d3c4e8b4-1 00:03:16.556 --> 00:03:20.067 to obtain a binding ruling or from seeking professional 4bdbfbb4-83d2-4c9c-b9ea-a2c4d3c4e8b4-2 00:03:20.067 --> 00:03:23.955 advice, such as from a licensed customs broker or a qualified 4bdbfbb4-83d2-4c9c-b9ea-a2c4d3c4e8b4-3 00:03:23.955 --> 00:03:24.520 attorney. 071dd021-55f7-4e43-8cc2-0fc899e5ba76-0 00:03:27.720 --> 00:03:31.493 The media contained in this presentation was either produced 071dd021-55f7-4e43-8cc2-0fc899e5ba76-1 00:03:31.493 --> 00:03:35.329 by CBP or it was obtained online with effort to source public 071dd021-55f7-4e43-8cc2-0fc899e5ba76-2 00:03:35.329 --> 00:03:37.680 domain or Creative Commons materials. 1734116f-1724-40cd-8ecb-83b5f10b1bd2-0 00:03:38.560 --> 00:03:41.920 The media provided here is for educational purposes only. 72950425-1158-42db-8930-e3d73893ccd8-0 00:03:45.280 --> 00:03:49.378 For our outside participants, we highly recommend obtaining a 72950425-1158-42db-8930-e3d73893ccd8-1 00:03:49.378 --> 00:03:53.543 ruling from CBP, especially when the issue is in doubt or it's 72950425-1158-42db-8930-e3d73893ccd8-2 00:03:53.543 --> 00:03:56.650 complex issues like classification, country of 72950425-1158-42db-8930-e3d73893ccd8-3 00:03:56.650 --> 00:04:00.551 origin, or whether or not Section 3O1 duties apply to your 72950425-1158-42db-8930-e3d73893ccd8-4 00:04:00.551 --> 00:04:01.080 product. 8474b325-cdbb-495b-a9bf-bb74640bd06a-0 00:04:01.240 --> 00:04:03.880 These are all reasons to apply for a binding ruling. 33a51fa6-cff1-4187-bfef-cd0b09537553-0 00:04:08.680 --> 00:04:11.800 Once the webinars have been completed and prepped, they will 33a51fa6-cff1-4187-bfef-cd0b09537553-1 00:04:11.800 --> 00:04:14.510 be available to our outside participants at this web 33a51fa6-cff1-4187-bfef-cd0b09537553-2 00:04:14.510 --> 00:04:14.920 address. 71704c7a-8ff7-4e12-ba29-ea9d4359c833-0 00:04:15.680 --> 00:04:18.408 The internal participants can get the webinar recording 71704c7a-8ff7-4e12-ba29-ea9d4359c833-1 00:04:18.408 --> 00:04:21.040 through our Office of Trade internal SharePoint site. 91d16de8-3e98-465a-9200-aad7262781cc-0 00:04:22.520 --> 00:04:25.650 I'm going to repeat this web address in a couple slides, and 91d16de8-3e98-465a-9200-aad7262781cc-1 00:04:25.650 --> 00:04:27.960 I'll have more time for you to copy it down. 8775a40e-b3a7-4da3-9196-ffbc3b7e9ad6-0 00:04:29.920 --> 00:04:33.376 OK, so today's webinar is supposed to be limited to one 8775a40e-b3a7-4da3-9196-ffbc3b7e9ad6-1 00:04:33.376 --> 00:04:36.400 hour, and we have a lot of information to cover. 4b6e7f21-4774-4bda-a5a8-1e6a9302df6d-0 00:04:37.440 --> 00:04:40.874 So we'll begin by recapping last year's webinar, which was titled 4b6e7f21-4774-4bda-a5a8-1e6a9302df6d-1 00:04:40.874 --> 00:04:42.280 Industrial Controls Part 1. 5204d1d2-a188-4a5c-9219-d5aae2fd226c-0 00:04:43.880 --> 00:04:46.640 This was held in August of 2023. af2e1985-b9dc-4b93-946f-53ad02132557-0 00:04:48.720 --> 00:04:51.963 We're not going to go over the same information as Part 1, so af2e1985-b9dc-4b93-946f-53ad02132557-1 00:04:51.963 --> 00:04:55.206 we're only going to go over the legal notes very briefly, and af2e1985-b9dc-4b93-946f-53ad02132557-2 00:04:55.206 --> 00:04:58.449 then we're going to go over the tariff headings, provide some af2e1985-b9dc-4b93-946f-53ad02132557-3 00:04:58.449 --> 00:05:01.796 general classification examples, and hopefully at the end we'll af2e1985-b9dc-4b93-946f-53ad02132557-4 00:05:01.796 --> 00:05:03.679 have some time to answer questions. a00134cd-f57a-4bc9-9fad-519c594103b4-0 00:05:07.800 --> 00:05:10.840 Here's that webinar address again at the bottom. 5a290616-2828-4d3c-ad84-16684502629b-0 00:05:12.040 --> 00:05:15.322 If you didn't attend the first webinar on industrial controls, 5a290616-2828-4d3c-ad84-16684502629b-1 00:05:15.322 --> 00:05:17.720 I recommend you try to go back and review it. 7f0d3274-db91-4bbd-83f0-cd6d02e9d3dd-0 00:05:18.440 --> 00:05:21.925 We tried to do something a bit different by breaking out the 7f0d3274-db91-4bbd-83f0-cd6d02e9d3dd-1 00:05:21.925 --> 00:05:25.297 webinars in two or three parts, each one building upon the 7f0d3274-db91-4bbd-83f0-cd6d02e9d3dd-2 00:05:25.297 --> 00:05:25.640 other. 9ee043f0-6a9f-4257-92b9-262fdd376db1-0 00:05:26.400 --> 00:05:31.266 The entire goal of Part 1 was to set the stage for us to discuss 9ee043f0-6a9f-4257-92b9-262fdd376db1-1 00:05:31.266 --> 00:05:32.240 heading 8537. 129d1eb4-78f1-4fb5-a20e-cd5d6bd68198-0 00:05:33.080 --> 00:05:37.493 If you remember, in the first webinar, we covered the legal 129d1eb4-78f1-4fb5-a20e-cd5d6bd68198-1 00:05:37.493 --> 00:05:41.465 notes that apply to Section 16 and Chapter 85, and we 129d1eb4-78f1-4fb5-a20e-cd5d6bd68198-2 00:05:41.465 --> 00:05:45.364 introduced the various electrical apparatus that are 129d1eb4-78f1-4fb5-a20e-cd5d6bd68198-3 00:05:45.364 --> 00:05:48.160 classified in headings 8535 and 8536. b5b1a3fa-5214-4287-ad32-5914916016d5-0 00:05:50.360 --> 00:05:53.960 Devices like circuit Breakers and switches, relays, and all b5b1a3fa-5214-4287-ad32-5914916016d5-1 00:05:53.960 --> 00:05:57.500 sorts of machinery that perform an electrical switching or b5b1a3fa-5214-4287-ad32-5914916016d5-2 00:05:57.500 --> 00:05:59.360 electrical protection function. c3613af9-0130-42e8-bfac-9b4394802197-0 00:05:59.640 --> 00:06:03.064 These are all classified in those headings and they directly c3613af9-0130-42e8-bfac-9b4394802197-1 00:06:03.064 --> 00:06:06.040 correlate to our topic today, which is heading 8537. a4113315-5742-48f5-a5a3-4da77ab584c4-0 00:06:07.560 --> 00:06:11.458 Our thinking was that discussing headings 8535 and 36 do that a4113315-5742-48f5-a5a3-4da77ab584c4-1 00:06:11.458 --> 00:06:15.106 first and it will give the viewers a better understanding a4113315-5742-48f5-a5a3-4da77ab584c4-2 00:06:15.106 --> 00:06:18.879 of heading 8537 and hopefully this will all become clear in a4113315-5742-48f5-a5a3-4da77ab584c4-3 00:06:18.879 --> 00:06:19.760 the next hour. 66fb5383-cf82-4840-ba41-a76d36dc1ca4-0 00:06:20.960 --> 00:06:23.880 So check out the first webinar if you have some extra time. fe0ad7e3-71f5-4002-948f-8305c4882465-0 00:06:25.760 --> 00:06:28.880 OK, so let's talk about industrial control systems. 096b229c-1b51-42ec-acf9-a12524285219-0 00:06:30.400 --> 00:06:35.400 This is the formal explanation of industrial controls. df6adca7-861b-4c13-9e3c-c11a9843d6ed-0 00:06:36.480 --> 00:06:39.921 Today we're going to introduce electrical control and df6adca7-861b-4c13-9e3c-c11a9843d6ed-1 00:06:39.921 --> 00:06:43.362 electrical distribution apparatus that play a role in df6adca7-861b-4c13-9e3c-c11a9843d6ed-2 00:06:43.362 --> 00:06:46.867 these industrial control systems, whether it's being a df6adca7-861b-4c13-9e3c-c11a9843d6ed-3 00:06:46.867 --> 00:06:51.073 part of that system or maybe the machine itself can be considered df6adca7-861b-4c13-9e3c-c11a9843d6ed-4 00:06:51.073 --> 00:06:51.519 an ICS. 37870e4e-06de-4a65-9aa4-11e5ed7ffb82-0 00:06:52.480 --> 00:06:55.312 We'll go over some examples throughout the presentation that 37870e4e-06de-4a65-9aa4-11e5ed7ffb82-1 00:06:55.312 --> 00:06:56.520 will make this more clear. 15dc3d89-a746-4918-857e-d02c382435e6-0 00:06:59.320 --> 00:07:03.812 For example, we have these three pictures here that were also in 15dc3d89-a746-4918-857e-d02c382435e6-1 00:07:03.812 --> 00:07:07.336 the previous webinar, manufacturing control panels 15dc3d89-a746-4918-857e-d02c382435e6-2 00:07:07.336 --> 00:07:11.759 that are attached to production machinery like the one depicted 15dc3d89-a746-4918-857e-d02c382435e6-3 00:07:11.759 --> 00:07:12.519 here above. 8992e88d-f30b-4f37-857c-c89d12eec61a-0 00:07:13.680 --> 00:07:16.928 Inside this metal enclosure are switches and contactors and 8992e88d-f30b-4f37-857c-c89d12eec61a-1 00:07:16.928 --> 00:07:20.340 maybe some type of communication device, but its purpose is to 8992e88d-f30b-4f37-857c-c89d12eec61a-2 00:07:20.340 --> 00:07:21.640 control the robotic arm. dd8a27e3-98ef-4268-a9e0-c280a4df6ca9-0 00:07:22.840 --> 00:07:25.981 The second picture deals directly with the distribution dd8a27e3-98ef-4268-a9e0-c280a4df6ca9-1 00:07:25.981 --> 00:07:29.234 of electricity and heading 8537 specifically provides for dd8a27e3-98ef-4268-a9e0-c280a4df6ca9-2 00:07:29.234 --> 00:07:32.320 programmable controllers, which you see at the bottom. a5ac6f3c-30c1-4364-8af2-5e841ed7a613-0 00:07:33.720 --> 00:07:37.538 Just keep in mind that today we're going to talk about what a5ac6f3c-30c1-4364-8af2-5e841ed7a613-1 00:07:37.538 --> 00:07:41.484 industrial controls means within the context of Heading 8537, a5ac6f3c-30c1-4364-8af2-5e841ed7a613-2 00:07:41.484 --> 00:07:44.794 because obviously not every electrical machine in a a5ac6f3c-30c1-4364-8af2-5e841ed7a613-3 00:07:44.794 --> 00:07:48.040 manufacturing plant is covered under Heading 8537. a85ba2b0-0e57-4737-8bac-bdcaa99ff58d-0 00:07:51.320 --> 00:07:53.800 Just a recap of the legal notes. 50ee7fdb-fc9f-44af-8678-db82f35f758a-0 00:07:54.720 --> 00:07:59.768 Section 16 O1 identifies the exclusions to the section most 50ee7fdb-fc9f-44af-8678-db82f35f758a-1 00:07:59.768 --> 00:08:05.154 applicable to today's topic is NO1M, which excludes articles of 50ee7fdb-fc9f-44af-8678-db82f35f758a-2 00:08:05.154 --> 00:08:06.080 Chapter 90. 6a97fa96-36ef-4d9e-a8e5-4d65a0fb2e8a-0 00:08:07.240 --> 00:08:10.457 There's a little twist to this exclusion that we'll explain 6a97fa96-36ef-4d9e-a8e5-4d65a0fb2e8a-1 00:08:10.457 --> 00:08:12.120 more later on the presentation. 922d0ce8-dd0b-42fa-b4d4-4bf2f859c7b7-0 00:08:14.000 --> 00:08:17.959 Note 2 instructs us how to classify parts of machines that 922d0ce8-dd0b-42fa-b4d4-4bf2f859c7b7-1 00:08:17.959 --> 00:08:21.718 are classifiable in Chapters 84 and 85, and it lays the 922d0ce8-dd0b-42fa-b4d4-4bf2f859c7b7-2 00:08:21.718 --> 00:08:26.013 groundwork for how we classify those parts, either in their own 922d0ce8-dd0b-42fa-b4d4-4bf2f859c7b7-3 00:08:26.013 --> 00:08:29.973 specific tariff number or as part of the machine that they 922d0ce8-dd0b-42fa-b4d4-4bf2f859c7b7-4 00:08:29.973 --> 00:08:31.920 are intended to be used with. fc3d7c79-5b67-4c68-ac52-0783c018308d-0 00:08:33.640 --> 00:08:37.134 Note 3 is very important because we're instructed to identify a fc3d7c79-5b67-4c68-ac52-0783c018308d-1 00:08:37.134 --> 00:08:40.300 machine's principal function and to classify that machine fc3d7c79-5b67-4c68-ac52-0783c018308d-2 00:08:40.300 --> 00:08:41.720 according to the function. 6fd60f07-e796-45a0-84bf-a81bae9dc559-0 00:08:44.160 --> 00:08:47.987 And Note 4 to Section 16 talks about when a machine or a 6fd60f07-e796-45a0-84bf-a81bae9dc559-1 00:08:47.987 --> 00:08:51.681 combination of interconnected machines are intended to 6fd60f07-e796-45a0-84bf-a81bae9dc559-2 00:08:51.681 --> 00:08:56.113 contribute together to a clearly defined function were instructed 6fd60f07-e796-45a0-84bf-a81bae9dc559-3 00:08:56.113 --> 00:08:58.800 to classify according to that function. 5a11a0da-43f6-4913-b715-f2a5918394eb-0 00:08:59.160 --> 00:09:01.040 We refer to this as the functional unit. 44447aa1-1b59-4fc1-a56b-169595494d70-0 00:09:03.560 --> 00:09:07.208 It's likely that from all the webinars you've attended from 44447aa1-1b59-4fc1-a56b-169595494d70-1 00:09:07.208 --> 00:09:10.916 the electronics branch, you've been told over and over again 44447aa1-1b59-4fc1-a56b-169595494d70-2 00:09:10.916 --> 00:09:12.680 that we classify by function. 534df190-d08f-4991-8c4c-1cacb2e99c39-0 00:09:12.680 --> 00:09:16.560 In section 16, we'll classify by name. 11b6b7b5-6606-4af1-a846-b8965f692715-0 00:09:16.640 --> 00:09:20.200 We don't classify by composition, but by function. be1707bc-34de-4178-b834-ac1d0a9b0e15-0 00:09:21.320 --> 00:09:25.680 There are many reasons why we don't classify by name. d77a65a6-6a52-43b6-bd05-6b2f01632091-0 00:09:26.840 --> 00:09:30.160 Consider the terms computer or switch or controller. 62088c15-cb6a-4f15-bcb5-18a414dc847a-0 00:09:30.400 --> 00:09:32.789 Each of these terms have multiple meanings and describe 62088c15-cb6a-4f15-bcb5-18a414dc847a-1 00:09:32.789 --> 00:09:35.008 different articles that are classified in different 62088c15-cb6a-4f15-bcb5-18a414dc847a-2 00:09:35.008 --> 00:09:35.520 subheadings. 68a81d38-0657-4443-a86a-c1a823c99721-0 00:09:41.160 --> 00:09:45.051 Remembering that headings 8535 and 8536 cover all electrical 68a81d38-0657-4443-a86a-c1a823c99721-1 00:09:45.051 --> 00:09:48.560 switching and protection apparatus, What's immediately 68a81d38-0657-4443-a86a-c1a823c99721-2 00:09:48.560 --> 00:09:52.197 noticeable from this slide in the green area is that the 68a81d38-0657-4443-a86a-c1a823c99721-3 00:09:52.197 --> 00:09:55.706 difference between the two headings is essentially the 68a81d38-0657-4443-a86a-c1a823c99721-4 00:09:55.706 --> 00:09:58.960 maximum voltage level of the machine or apparatus. 17b8f808-7598-48a5-8118-17cea761488e-0 00:10:00.160 --> 00:10:04.634 Heading 8535 is for electrical apparatus for the maximum 17b8f808-7598-48a5-8118-17cea761488e-1 00:10:04.634 --> 00:10:09.736 voltage of more than 1000 volts, and heading 8536 is at or under 17b8f808-7598-48a5-8118-17cea761488e-2 00:10:09.736 --> 00:10:10.599 1000 volts. b6d73c68-1709-489f-9d64-8b1aa9e509e5-0 00:10:13.520 --> 00:10:17.789 Now that we're diving into 8537, we can see here that it's b6d73c68-1709-489f-9d64-8b1aa9e509e5-1 00:10:17.789 --> 00:10:22.421 made-up of multiple apparatus of headings 8535 and 8536, but it b6d73c68-1709-489f-9d64-8b1aa9e509e5-2 00:10:22.421 --> 00:10:26.040 too is divided by voltages of 1000 volts or less. 50305b89-efd9-48b9-b2c2-dd1035347386-0 00:10:30.920 --> 00:10:36.063 Heading 8537 provides four boards, panels, consoles, desks, 50305b89-efd9-48b9-b2c2-dd1035347386-1 00:10:36.063 --> 00:10:40.521 cabinets, and other bases equipped with two or more 50305b89-efd9-48b9-b2c2-dd1035347386-2 00:10:40.521 --> 00:10:45.837 apparatus of heading 8535 or 8536, or the electric control or 50305b89-efd9-48b9-b2c2-dd1035347386-3 00:10:45.837 --> 00:10:51.238 the distribution of electricity, including those incorporating 50305b89-efd9-48b9-b2c2-dd1035347386-4 00:10:51.238 --> 00:10:56.467 instruments or apparatus of Chapter 90 and numerical control 50305b89-efd9-48b9-b2c2-dd1035347386-5 00:10:56.467 --> 00:11:01.440 apparatus other than switching apparatus of heading 8517. 83d38e01-90a7-471f-9266-a88c44037059-0 00:11:03.960 --> 00:11:06.713 So if you look on the screen, these are the three requirements 83d38e01-90a7-471f-9266-a88c44037059-1 00:11:06.713 --> 00:11:08.200 to be classified in this heading. 4114b20e-117a-45c0-a435-0661b5340c42-0 00:11:09.320 --> 00:11:12.803 Based on a plain reading of the heading text, we know that a 4114b20e-117a-45c0-a435-0661b5340c42-1 00:11:12.803 --> 00:11:16.287 base is required and that the base must be equipped with two 4114b20e-117a-45c0-a435-0661b5340c42-2 00:11:16.287 --> 00:11:18.800 or more apparatus of headings 8535 or 8536. 3e4dec44-32ed-4362-a324-64165fe4ac06-0 00:11:20.040 --> 00:11:23.512 We're instructed that an apparatus or an instrument of 3e4dec44-32ed-4362-a324-64165fe4ac06-1 00:11:23.512 --> 00:11:27.552 Chapter 90 is allowable, and the heading specifically calls for 3e4dec44-32ed-4362-a324-64165fe4ac06-2 00:11:27.552 --> 00:11:29.319 numerical control apparatus. 33c3e936-11aa-4e4a-ae7b-ea6824ff87d3-0 00:11:30.400 --> 00:11:35.205 The heading also specifically excludes telecommunications 33c3e936-11aa-4e4a-ae7b-ea6824ff87d3-1 00:11:35.205 --> 00:11:37.360 apparatus of heading 8517. 65c0bb29-7085-4e91-9eb7-4bfecd0dd4fe-0 00:11:40.840 --> 00:11:44.747 One point to consider is that we could be looking at a collection 65c0bb29-7085-4e91-9eb7-4bfecd0dd4fe-1 00:11:44.747 --> 00:11:45.280 of bases. 7b71b966-a084-4529-8d35-3f91b2088980-0 00:11:45.760 --> 00:11:49.624 Nothing in the tariff or the explanatory notes prohibits us 7b71b966-a084-4529-8d35-3f91b2088980-1 00:11:49.624 --> 00:11:53.683 from classifying the machine of heading 8537 that incorporates 7b71b966-a084-4529-8d35-3f91b2088980-2 00:11:53.683 --> 00:11:55.680 other machines of heading 8537. 51a5ad63-8f3a-485b-8682-bdb659960230-0 00:11:56.360 --> 00:12:00.080 As long as the three rules are met and the principal function 51a5ad63-8f3a-485b-8682-bdb659960230-1 00:12:00.080 --> 00:12:03.140 of the machine is electrical control or electrical 51a5ad63-8f3a-485b-8682-bdb659960230-2 00:12:03.140 --> 00:12:06.200 distribution, then 8537 is completely appropriate. 7cd8f6d9-5ced-4646-b07c-b2489386990e-0 00:12:07.320 --> 00:12:10.067 This will become more clear when we go over motor control 7cd8f6d9-5ced-4646-b07c-b2489386990e-1 00:12:10.067 --> 00:12:12.200 centers, switchboards and other controllers. 8fabe76e-6dfb-4cba-8c72-c1f71134bd5f-0 00:12:17.680 --> 00:12:21.129 The explanatory notes leave the door wide open to what is 8fabe76e-6dfb-4cba-8c72-c1f71134bd5f-1 00:12:21.129 --> 00:12:22.200 considered a base. af04123d-d617-4d4b-8c84-9b2c676e83c6-0 00:12:23.200 --> 00:12:27.426 So the tariff heading text says and other bases, and now the af04123d-d617-4d4b-8c84-9b2c676e83c6-1 00:12:27.426 --> 00:12:30.960 electric explanatory notes leave us with etcetera. b2f6a4b8-0e27-4f95-a4f0-ffd53ab2d31e-0 00:12:32.600 --> 00:12:35.040 So we should be open to different types of bases. 26027f94-6286-4677-b7ff-04eeff522488-0 00:12:35.680 --> 00:12:38.572 The explanatory notes also give us examples of the types of 26027f94-6286-4677-b7ff-04eeff522488-1 00:12:38.572 --> 00:12:41.080 electrical apparatus that are amounted to the base. 45f336ff-97e0-4d94-95e3-87e5fcc6ca3e-0 00:12:42.280 --> 00:12:46.103 And we're provided with the last, the last portion of this 45f336ff-97e0-4d94-95e3-87e5fcc6ca3e-1 00:12:46.103 --> 00:12:49.668 slide that says including assemblies of several of the 45f336ff-97e0-4d94-95e3-87e5fcc6ca3e-2 00:12:49.668 --> 00:12:52.520 articles cited in the text of this heading. 2eb392bc-5b64-4597-ac13-4247c453d874-0 00:12:53.440 --> 00:12:57.567 So multiple machines that are classifiable under heading 8537 2eb392bc-5b64-4597-ac13-4247c453d874-1 00:12:57.567 --> 00:13:01.827 that are mounted to a base would still be classified in heading 2eb392bc-5b64-4597-ac13-4247c453d874-2 00:13:01.827 --> 00:13:02.160 8537. edffe374-a953-435a-b215-a964d44ae106-0 00:13:03.840 --> 00:13:06.600 So let's talk about the three heading requirements. 55a26308-8362-4b11-8502-5dccd1328ac3-0 00:13:09.400 --> 00:13:13.550 The next few slides we're going to parse out the heading 55a26308-8362-4b11-8502-5dccd1328ac3-1 00:13:13.550 --> 00:13:15.080 requirements of 8537. df97aef9-4f29-4c35-b3a9-b952bd93b167-0 00:13:15.960 --> 00:13:19.440 We start off with what the tariff calls a base. 299ec493-c411-47bd-84d5-ba1e99070e0b-0 00:13:21.160 --> 00:13:24.201 While we get some examples of bases from the heading text and 299ec493-c411-47bd-84d5-ba1e99070e0b-1 00:13:24.201 --> 00:13:27.340 the explanatory notes, the term base is not defined anywhere in 299ec493-c411-47bd-84d5-ba1e99070e0b-2 00:13:27.340 --> 00:13:27.880 the tariff. 8e919133-6ddd-4f7c-9d49-e15b1a343c28-0 00:13:29.200 --> 00:13:33.371 Some basic dictionary definitions include the layer of 8e919133-6ddd-4f7c-9d49-e15b1a343c28-1 00:13:33.371 --> 00:13:37.694 something on which other elements are added, or the part 8e919133-6ddd-4f7c-9d49-e15b1a343c28-2 00:13:37.694 --> 00:13:40.880 of which something rests or is supported. 01536af2-5bd0-4f13-8329-8e64df479099-0 00:13:43.080 --> 00:13:46.971 So we should be prepared to identify a housing, A-frame, or 01536af2-5bd0-4f13-8329-8e64df479099-1 00:13:46.971 --> 00:13:49.890 anything really that incorporates electrical 01536af2-5bd0-4f13-8329-8e64df479099-2 00:13:49.890 --> 00:13:53.781 apparatus as a base, as long as the apparatus is mounted or 01536af2-5bd0-4f13-8329-8e64df479099-3 00:13:53.781 --> 00:13:54.560 fixed to it. 29d72e89-8fd5-4c39-be2a-3bf45c6f0977-0 00:13:58.200 --> 00:14:02.720 The second requirement says that we need two or more electrical 29d72e89-8fd5-4c39-be2a-3bf45c6f0977-1 00:14:02.720 --> 00:14:07.240 apparatus of headings 8535 and 8536 to be mounted to that base. 9289818f-7f85-4608-909f-bb3455f061fb-0 00:14:08.160 --> 00:14:12.980 Here are some examples of what is expected to be equipped to 9289818f-7f85-4608-909f-bb3455f061fb-1 00:14:12.980 --> 00:14:17.248 that base, fuses, relays, terminals, terminal blocks, 9289818f-7f85-4608-909f-bb3455f061fb-2 00:14:17.248 --> 00:14:17.959 etcetera. ccbd7d0b-d759-49f3-9168-686ce21cee5f-0 00:14:24.900 --> 00:14:27.580 The next requirement is its function. e40e84cd-2d92-427c-948a-d9d10a9db00c-0 00:14:29.260 --> 00:14:32.996 Control is a verb that means having to direct, influence, e40e84cd-2d92-427c-948a-d9d10a9db00c-1 00:14:32.996 --> 00:14:34.800 manage something or someone. 69e8a2cc-dc88-4089-af67-fe33f4c713fb-0 00:14:35.280 --> 00:14:39.660 It can also be a noun that means the power to make decisions, the 69e8a2cc-dc88-4089-af67-fe33f4c713fb-1 00:14:39.660 --> 00:14:44.040 ability to direct actions or the amount of something limited, and 69e8a2cc-dc88-4089-af67-fe33f4c713fb-2 00:14:44.040 --> 00:14:47.624 to distribute us to share or deliver something out to 69e8a2cc-dc88-4089-af67-fe33f4c713fb-3 00:14:47.624 --> 00:14:51.539 multiple recipients, or in this case, electrical circuits, 69e8a2cc-dc88-4089-af67-fe33f4c713fb-4 00:14:51.539 --> 00:14:52.999 machines or locations. 0f10767f-f67c-4681-a0d2-b85a0a34e13a-0 00:15:01.000 --> 00:15:05.858 These machines may incorporate instruments of or apparatus of 0f10767f-f67c-4681-a0d2-b85a0a34e13a-1 00:15:05.858 --> 00:15:06.720 Chapter 90. 6180404f-964d-43d1-810b-20870769b3a9-0 00:15:07.680 --> 00:15:10.684 You might say well wait a minute, I thought you said that 6180404f-964d-43d1-810b-20870769b3a9-1 00:15:10.684 --> 00:15:13.120 Section 16O1M excluded articles of Chapter 90. 6db4811e-ff68-49e4-a555-32b16bca94a1-0 00:15:13.760 --> 00:15:15.080 Well, yes, that is true. ff8b37d4-098a-4a9c-8141-ee66d6e53eed-0 00:15:15.080 --> 00:15:16.160 It does exclude. 82584fb5-0392-42b9-a269-a55b1f199472-0 00:15:17.000 --> 00:15:21.513 But we have to keep in mind that the requirement that we classify 82584fb5-0392-42b9-a269-a55b1f199472-1 00:15:21.513 --> 00:15:25.480 in Section 16 and also Chapter 90 as well is by function. edf4fac1-8ff4-4819-9ad5-91c0173e9629-0 00:15:26.240 --> 00:15:30.461 So a large industrial cabinet at a power generation facility will edf4fac1-8ff4-4819-9ad5-91c0173e9629-1 00:15:30.461 --> 00:15:34.554 undoubtedly contain meters and instrumentation, but the cabinet edf4fac1-8ff4-4819-9ad5-91c0173e9629-2 00:15:34.554 --> 00:15:38.520 itself may have the principal function of electrical control. 0ab8adac-fa79-4d79-9bcd-9ec14cf5c9cb-0 00:15:39.200 --> 00:15:42.398 That's when we start to look at all the functions and machine 0ab8adac-fa79-4d79-9bcd-9ec14cf5c9cb-1 00:15:42.398 --> 00:15:45.339 performs and decide which function can be considered its 0ab8adac-fa79-4d79-9bcd-9ec14cf5c9cb-2 00:15:45.339 --> 00:15:46.320 principal function. 87c99dc5-74f9-4725-a0e3-41895224060f-0 00:15:47.280 --> 00:15:50.393 In this example, a Power Distribution cabinet that 87c99dc5-74f9-4725-a0e3-41895224060f-1 00:15:50.393 --> 00:15:54.116 contains a voltage meter, we would likely say that the meter 87c99dc5-74f9-4725-a0e3-41895224060f-2 00:15:54.116 --> 00:15:57.840 is a subsidiary to the function of control and distribution. 33480cd4-32f5-45db-85b8-9321fbe5f877-0 00:16:00.160 --> 00:16:04.206 And when we talk about switching apparatus, the heading language 33480cd4-32f5-45db-85b8-9321fbe5f877-1 00:16:04.206 --> 00:16:08.003 explicitly excludes machines of heading 8517, which includes 33480cd4-32f5-45db-85b8-9321fbe5f877-2 00:16:08.003 --> 00:16:10.680 data transmission and reception apparatus. 2ca475bd-1725-48d6-85fb-c5dd0997b1a8-0 00:16:11.600 --> 00:16:15.200 This is why it is so important that we classify machines of 2ca475bd-1725-48d6-85fb-c5dd0997b1a8-1 00:16:15.200 --> 00:16:18.980 this section by function and not by name, because as the slide 2ca475bd-1725-48d6-85fb-c5dd0997b1a8-2 00:16:18.980 --> 00:16:22.040 shows, the term switch can have multiple meanings. af36538c-792e-4300-95d4-02dd98b635df-0 00:16:23.400 --> 00:16:26.589 Now, at some point we're going to have to go into detail on af36538c-792e-4300-95d4-02dd98b635df-1 00:16:26.589 --> 00:16:29.513 things like programmable controllers and other control af36538c-792e-4300-95d4-02dd98b635df-2 00:16:29.513 --> 00:16:32.702 cabinets, and you're going to see that inside some of these af36538c-792e-4300-95d4-02dd98b635df-3 00:16:32.702 --> 00:16:36.104 configurations are communication modules, or perhaps electrical af36538c-792e-4300-95d4-02dd98b635df-4 00:16:36.104 --> 00:16:39.347 controller itself provides a communication functional on its af36538c-792e-4300-95d4-02dd98b635df-5 00:16:39.347 --> 00:16:39.560 own. dd402912-f589-4131-a203-615f8a5cf12a-0 00:16:41.120 --> 00:16:44.528 Just like the Chapter 90 provision, an electrical control dd402912-f589-4131-a203-615f8a5cf12a-1 00:16:44.528 --> 00:16:47.937 cabinet can have a communication feature, but the overall dd402912-f589-4131-a203-615f8a5cf12a-2 00:16:47.937 --> 00:16:51.229 function or principal function is electrical control or dd402912-f589-4131-a203-615f8a5cf12a-3 00:16:51.229 --> 00:16:52.640 electrical distribution. c69db513-f9ac-4773-b060-d1e70d975bc4-0 00:16:56.880 --> 00:17:01.126 Here is a basic example of something classified and heading c69db513-f9ac-4773-b060-d1e70d975bc4-1 00:17:01.126 --> 00:17:01.480 8537. 68b84e25-607a-4fe6-97ef-aed28792c982-0 00:17:03.240 --> 00:17:06.245 This is a Power Distribution module that can turn a circuit 68b84e25-607a-4fe6-97ef-aed28792c982-1 00:17:06.245 --> 00:17:08.600 on and off by a low voltage controller signal. 3e77e7e9-5e4b-4458-8c20-e39c56bdc045-0 00:17:09.040 --> 00:17:12.394 It's simple, with just a printed circuit port assembly, a single 3e77e7e9-5e4b-4458-8c20-e39c56bdc045-1 00:17:12.394 --> 00:17:13.840 relay, and a terminal block. 6cde60ee-dc82-49bc-b92a-7ab7219429c8-0 00:17:15.160 --> 00:17:18.431 And for today, just because we're focusing on industrial 6cde60ee-dc82-49bc-b92a-7ab7219429c8-1 00:17:18.431 --> 00:17:21.874 control machines, don't get the wrong idea that the heading 6cde60ee-dc82-49bc-b92a-7ab7219429c8-2 00:17:21.874 --> 00:17:25.490 requires that all the machines or apparatus classified in 8537 6cde60ee-dc82-49bc-b92a-7ab7219429c8-3 00:17:25.490 --> 00:17:28.360 are dedicated to industrial control applications. 68a495e6-b2d3-476d-8a51-301f7c0a86d5-0 00:17:29.240 --> 00:17:33.320 Is every printed circuit board assembly classified in 8537? d2ef394c-fad7-4523-8e19-2ec1c4d548fd-0 00:17:34.360 --> 00:17:35.440 No, of course not. b3049041-a03a-4aa5-b75c-dc3324777c27-0 00:17:35.760 --> 00:17:39.831 Likewise, is everything that is classified in 8537 an industrial b3049041-a03a-4aa5-b75c-dc3324777c27-1 00:17:39.831 --> 00:17:40.520 controller? 5ce4045d-12fc-4722-9090-5f5a788bc11f-0 00:17:41.560 --> 00:17:41.960 No. 95e67d61-669b-4100-93d6-3329d8322009-0 00:17:42.600 --> 00:17:45.760 Here are some examples you'll see from these rulings. a5cfb9e8-7f53-40ee-aac0-2acc336f3a72-0 00:17:45.760 --> 00:17:49.151 We have a pump controller, refrigerator control boards, a5cfb9e8-7f53-40ee-aac0-2acc336f3a72-1 00:17:49.151 --> 00:17:52.240 power strips, and surge protectors for your house. 3d94a72e-e380-4f1d-acb4-a643aae6d7e6-0 00:17:53.560 --> 00:17:56.354 The take away from this slide should be that we're only 3d94a72e-e380-4f1d-acb4-a643aae6d7e6-1 00:17:56.354 --> 00:17:58.600 looking to satisfy the heading requirements. c8934c4a-610b-4215-8c9f-68d319d7367f-0 00:17:58.640 --> 00:18:05.824 The machine can be simple, just like this little relay board, c8934c4a-610b-4215-8c9f-68d319d7367f-1 00:18:05.824 --> 00:18:09.880 but they can also be very complex. ff108c67-368a-4ffd-aeeb-de0f2490bc59-0 00:18:10.880 --> 00:18:14.432 Here is an industrial control cabinet that houses hundreds of ff108c67-368a-4ffd-aeeb-de0f2490bc59-1 00:18:14.432 --> 00:18:17.583 electrical terminals and switches, relays, contactors, ff108c67-368a-4ffd-aeeb-de0f2490bc59-2 00:18:17.583 --> 00:18:21.078 circuit Breakers, and more, and it functions to electrically ff108c67-368a-4ffd-aeeb-de0f2490bc59-3 00:18:21.078 --> 00:18:24.230 control other machines and distribute electricity in a ff108c67-368a-4ffd-aeeb-de0f2490bc59-4 00:18:24.230 --> 00:18:25.720 manufacturing environment. 1a17e0ca-f434-4739-8d6f-eb5ac663b43b-0 00:18:27.000 --> 00:18:27.600 It's easy. 3b69353b-a404-49fb-accd-f83761ab8679-0 00:18:27.600 --> 00:18:31.905 It's easy to see how this can satisfy our heading requirements 3b69353b-a404-49fb-accd-f83761ab8679-1 00:18:31.905 --> 00:18:32.520 for 8537. 9ab1e546-b620-47cc-b2e1-ada1e36950f2-0 00:18:33.680 --> 00:18:38.243 Some industrial control examples are noted here, such as the 9ab1e546-b620-47cc-b2e1-ada1e36950f2-1 00:18:38.243 --> 00:18:41.760 control cabinet, switchboards and controllers. eccadaac-2208-4c82-869a-15eae5faac6f-0 00:18:47.440 --> 00:18:50.560 So far we've done a short summary of the webinar from last eccadaac-2208-4c82-869a-15eae5faac6f-1 00:18:50.560 --> 00:18:53.840 year and we discussed the basic requirements of heading 8537. e774f353-a77a-42f9-a271-8a3b961b53ad-0 00:18:54.560 --> 00:18:57.761 Now that we're dialed in on the heading requirements and we're e774f353-a77a-42f9-a271-8a3b961b53ad-1 00:18:57.761 --> 00:19:00.556 classifying industrial controllers, let's take another e774f353-a77a-42f9-a271-8a3b961b53ad-2 00:19:00.556 --> 00:19:02.640 look at the tariff page of heading 8537. 6291c568-ebde-4761-9e55-0fbc99f6d6da-0 00:19:04.400 --> 00:19:08.510 The heading is divided by voltage not exceeding 1000 volts 6291c568-ebde-4761-9e55-0fbc99f6d6da-1 00:19:08.510 --> 00:19:10.600 and then exceeding 1000 volts. 5dd148cf-cc73-45c9-927b-81d4fa342b12-0 00:19:11.520 --> 00:19:15.387 Today's webinar is going to concentrate more on control 5dd148cf-cc73-45c9-927b-81d4fa342b12-1 00:19:15.387 --> 00:19:19.531 apparatus of 1000 volts or less and the shaded areas of the 5dd148cf-cc73-45c9-927b-81d4fa342b12-2 00:19:19.531 --> 00:19:20.360 tariff page. 0ef6dcbe-4adc-4209-b445-ddd28d3e4393-0 00:19:20.360 --> 00:19:24.800 Here we will not go over well. 0f2f4c9b-1897-465e-a4a5-f0992b3cdddc-0 00:19:24.800 --> 00:19:28.404 We will cover our motor control centers, or MCCS for short 0f2f4c9b-1897-465e-a4a5-f0992b3cdddc-1 00:19:28.404 --> 00:19:31.337 switchboards, distribution panels, programmable 0f2f4c9b-1897-465e-a4a5-f0992b3cdddc-2 00:19:31.337 --> 00:19:34.759 controllers, and some other control apparatus that fall 0f2f4c9b-1897-465e-a4a5-f0992b3cdddc-3 00:19:34.759 --> 00:19:35.920 within the heading. ca0ca778-f80c-40ff-bf60-0dae0bf0aee8-0 00:19:38.200 --> 00:19:41.964 The list of what can be classified in heading 8537 is ca0ca778-f80c-40ff-bf60-0dae0bf0aee8-1 00:19:41.964 --> 00:19:43.080 quite extensive. 69c592d3-edd7-4614-8f55-c0de39321e3f-0 00:19:43.720 --> 00:19:46.467 We just don't have the time to go too in depth, so we need to 69c592d3-edd7-4614-8f55-c0de39321e3f-1 00:19:46.467 --> 00:19:49.347 be picky about what we choose to go over and how detailed we can 69c592d3-edd7-4614-8f55-c0de39321e3f-2 00:19:49.347 --> 00:19:49.480 be. 7c9207bf-603a-43df-a278-137e65910127-0 00:19:55.120 --> 00:19:58.245 Explanatory notes for heading 8537 simply reiterate the 7c9207bf-603a-43df-a278-137e65910127-1 00:19:58.245 --> 00:20:01.650 heading requirements and don't really do the heading justice 7c9207bf-603a-43df-a278-137e65910127-2 00:20:01.650 --> 00:20:04.720 with all the machines that could be classifiable here. b906964b-f1a6-4625-8a4b-0f620a6b90d7-0 00:20:07.960 --> 00:20:11.947 But it does provide us with three of the machines that are b906964b-f1a6-4625-8a4b-0f620a6b90d7-1 00:20:11.947 --> 00:20:16.137 covered specifically, notably the numerical control apparatus b906964b-f1a6-4625-8a4b-0f620a6b90d7-2 00:20:16.137 --> 00:20:19.989 and the built with built in ADP machine and programmable b906964b-f1a6-4625-8a4b-0f620a6b90d7-3 00:20:19.989 --> 00:20:20.800 controllers. 871c2ec4-b87c-4ed7-9dce-68b669be1bf2-0 00:20:21.720 --> 00:20:23.000 We will go over them shortly. 559cf7c7-3336-4ae9-ad17-6f608084e201-0 00:20:23.000 --> 00:20:26.406 But from a computer or an ADP machine perspective, you must 559cf7c7-3336-4ae9-ad17-6f608084e201-1 00:20:26.406 --> 00:20:29.983 keep in mind that these machines or the collection of machines 559cf7c7-3336-4ae9-ad17-6f608084e201-2 00:20:29.983 --> 00:20:33.390 are performing an electrical control function, which is why 559cf7c7-3336-4ae9-ad17-6f608084e201-3 00:20:33.390 --> 00:20:36.400 they're not considered ADP machines of heading 8471. 0438772a-7ec0-491d-842d-2bd8f5d4912d-0 00:20:41.080 --> 00:20:44.113 The first subheading we're going to discuss is the motor Control 0438772a-7ec0-491d-842d-2bd8f5d4912d-1 00:20:44.113 --> 00:20:44.440 Center. ad5de006-83d1-4dbe-a80e-856cf56e17e8-0 00:20:46.040 --> 00:20:51.160 Motor control centers are classified in 8537106000. 6f395fa5-802b-4069-890a-753e28a08899-0 00:20:52.680 --> 00:20:56.344 Motor Control Center is an assembly of one or more enclosed 6f395fa5-802b-4069-890a-753e28a08899-1 00:20:56.344 --> 00:21:00.130 sections having a common power bus and principally containing 6f395fa5-802b-4069-890a-753e28a08899-2 00:21:00.130 --> 00:21:01.840 electric control components. d5e47aad-5d68-41fe-bcca-425d730ba51d-0 00:21:03.480 --> 00:21:06.784 The basic structure of an MCC is a metal cabinet where the d5e47aad-5d68-41fe-bcca-425d730ba51d-1 00:21:06.784 --> 00:21:10.368 vertical sections are isolated from one another and may contain d5e47aad-5d68-41fe-bcca-425d730ba51d-2 00:21:10.368 --> 00:21:13.952 one or more subsections, which are called buckets, cubicles, or d5e47aad-5d68-41fe-bcca-425d730ba51d-3 00:21:13.952 --> 00:21:14.680 compartments. 7fed4c22-6a0e-4df9-ae3f-8c75b793a3b5-0 00:21:15.440 --> 00:21:18.536 What they're called will be dependent upon the company that 7fed4c22-6a0e-4df9-ae3f-8c75b793a3b5-1 00:21:18.536 --> 00:21:21.427 you're working with, but today we're going to call them 7fed4c22-6a0e-4df9-ae3f-8c75b793a3b5-2 00:21:21.427 --> 00:21:21.840 buckets. a722e32a-1686-400a-b257-6ab5b601a164-0 00:21:23.680 --> 00:21:26.629 Each bucket is where the electrical apparatus that is a722e32a-1686-400a-b257-6ab5b601a164-1 00:21:26.629 --> 00:21:28.760 controlling electric motors is housed. 826ca34a-28a8-46e5-b8c7-44a8cac6eb26-0 00:21:30.200 --> 00:21:34.621 MCCS can be one single section or they can be numerous sections 826ca34a-28a8-46e5-b8c7-44a8cac6eb26-1 00:21:34.621 --> 00:21:36.280 that are interconnected. 638689d1-1a48-4085-8a14-c4c3df5981f7-0 00:21:37.000 --> 00:21:41.088 These sections may be detached from one another to facilitate 638689d1-1a48-4085-8a14-c4c3df5981f7-1 00:21:41.088 --> 00:21:45.243 shipping simply because a multi section MCC can weigh tons and 638689d1-1a48-4085-8a14-c4c3df5981f7-2 00:21:45.243 --> 00:21:49.332 it's common to palletize them in broken up sections and maybe 638689d1-1a48-4085-8a14-c4c3df5981f7-3 00:21:49.332 --> 00:21:50.520 even individually. dbea91ce-3cc0-4f59-929c-e4068994767c-0 00:21:51.240 --> 00:21:53.968 The MCC cabinets have an internal wire way that dbea91ce-3cc0-4f59-929c-e4068994767c-1 00:21:53.968 --> 00:21:57.435 distribute power to the buckets where the various electrical dbea91ce-3cc0-4f59-929c-e4068994767c-2 00:21:57.435 --> 00:21:58.800 apparatus are installed. de7f6dec-ca26-418e-90e2-cb5cf3aa36af-0 00:22:01.000 --> 00:22:05.878 The industry divides MCCS by either low voltage, which are de7f6dec-ca26-418e-90e2-cb5cf3aa36af-1 00:22:05.878 --> 00:22:10.921 for controlling motors from 230 volts to 1000 volts, or high de7f6dec-ca26-418e-90e2-cb5cf3aa36af-2 00:22:10.921 --> 00:22:15.800 voltage for controlling motors 1000 volts to 15,000 volts. 4971743b-23df-4dc6-8a9e-724f3298e299-0 00:22:16.760 --> 00:22:21.066 You will see terms like NEMA or IP rating and these refer to the 4971743b-23df-4dc6-8a9e-724f3298e299-1 00:22:21.066 --> 00:22:25.174 environmental protections and standards that the MCC is rated 4971743b-23df-4dc6-8a9e-724f3298e299-2 00:22:25.174 --> 00:22:25.440 for. 9e4e4ff8-d280-4ee5-9d31-d2a32a9c9d7f-0 00:22:34.440 --> 00:22:37.286 It's important to note that MCCS can house multiple types of 9e4e4ff8-d280-4ee5-9d31-d2a32a9c9d7f-1 00:22:37.286 --> 00:22:38.920 electrical machines and apparatus. 7f3f38a7-952f-4ee3-8905-dd2f8ddc0983-0 00:22:39.280 --> 00:22:42.678 For example, installed inside the MCC could be indicators, 7f3f38a7-952f-4ee3-8905-dd2f8ddc0983-1 00:22:42.678 --> 00:22:45.847 meters, current and voltage measuring apparatus, motor 7f3f38a7-952f-4ee3-8905-dd2f8ddc0983-2 00:22:45.847 --> 00:22:48.440 starters, terminal blocks, and so much more. 06ae6ab7-726c-445f-8569-3546bf1b5ecf-0 00:22:49.280 --> 00:22:54.214 But for an MCC to be classified in subheading 8537106000, 06ae6ab7-726c-445f-8569-3546bf1b5ecf-1 00:22:54.214 --> 00:22:59.320 controlling electric motors must be its principal function. 51b0280c-9857-4b74-804f-19fa859a9f50-0 00:23:00.200 --> 00:23:04.145 Here in this example, we see a circuit breaker, a fuse block, a 51b0280c-9857-4b74-804f-19fa859a9f50-1 00:23:04.145 --> 00:23:06.920 speed drive controller, and terminal blocks. a2513e8e-a7e4-49be-8cef-1eaead3e6097-0 00:23:07.560 --> 00:23:10.588 Is this bucket by itself classifiable as a motor Control a2513e8e-a7e4-49be-8cef-1eaead3e6097-1 00:23:10.588 --> 00:23:10.960 Center? d104d5ad-65bd-4bf8-8954-c1ac199efc92-0 00:23:12.680 --> 00:23:15.553 No, I don't think we would make this an MCC because we're d104d5ad-65bd-4bf8-8954-c1ac199efc92-1 00:23:15.553 --> 00:23:18.277 missing the fundamental structure of the enclosures in d104d5ad-65bd-4bf8-8954-c1ac199efc92-2 00:23:18.277 --> 00:23:19.120 the common buses. ba724e24-7b2e-44f8-a3e7-59a4c88289d1-0 00:23:20.280 --> 00:23:22.991 But if this bucket were installed inside of enclosure, ba724e24-7b2e-44f8-a3e7-59a4c88289d1-1 00:23:22.991 --> 00:23:25.408 the combination of the electrical apparatus does ba724e24-7b2e-44f8-a3e7-59a4c88289d1-2 00:23:25.408 --> 00:23:28.120 establish the function of controlling electric motors. 3609b2de-18e7-4f0f-bbc8-dd362dfca644-0 00:23:29.520 --> 00:23:32.746 But not all MCCS and their buckets are configured like 3609b2de-18e7-4f0f-bbc8-dd362dfca644-1 00:23:32.746 --> 00:23:33.040 this. 9f8fe564-57bd-4190-90a9-27ddee2595fe-0 00:23:33.440 --> 00:23:36.709 Some will contain an arrangement of motor starters or circuit 9f8fe564-57bd-4190-90a9-27ddee2595fe-1 00:23:36.709 --> 00:23:39.926 Breakers and indication lamps and push buttons, and may also 9f8fe564-57bd-4190-90a9-27ddee2595fe-2 00:23:39.926 --> 00:23:41.720 contain programmable controllers. 29870e12-37d1-441f-bda4-771bd83dd893-0 00:23:43.840 --> 00:23:46.052 This is where it gets complicated, because we're 29870e12-37d1-441f-bda4-771bd83dd893-1 00:23:46.052 --> 00:23:48.040 required to establish the overall function. 43611d33-0215-455f-bf78-711e33b49199-0 00:23:48.800 --> 00:23:51.418 But when the control apparatus are introduced, like 43611d33-0215-455f-bf78-711e33b49199-1 00:23:51.418 --> 00:23:54.690 programmable controllers, can we actually say that the principal 43611d33-0215-455f-bf78-711e33b49199-2 00:23:54.690 --> 00:23:56.000 function is motor control? 01f3085c-5109-4ea3-bc92-41f2dfef99bd-0 00:23:56.520 --> 00:23:59.280 Like everything in classification, it depends. a4a5a756-0652-4930-9e21-a04f85144d6e-0 00:24:00.280 --> 00:24:03.606 We're going to revisit MCCS later on after we've discussed a4a5a756-0652-4930-9e21-a04f85144d6e-1 00:24:03.606 --> 00:24:06.708 some of the other industrial control machines that are a4a5a756-0652-4930-9e21-a04f85144d6e-2 00:24:06.708 --> 00:24:08.400 classifiable and heading 8537. 2f407327-7adb-459a-82c8-a59d5cf1d9c4-0 00:24:13.960 --> 00:24:16.764 Following the SERF page down in order, we're presented with 2f407327-7adb-459a-82c8-a59d5cf1d9c4-1 00:24:16.764 --> 00:24:18.120 switch gear and switchboards. aeffe437-3a08-4787-90a5-80bb3164da12-0 00:24:18.960 --> 00:24:22.316 Switch gear and switchboards refer to the type of equipment aeffe437-3a08-4787-90a5-80bb3164da12-1 00:24:22.316 --> 00:24:25.561 used to manage and distribute power while also protecting aeffe437-3a08-4787-90a5-80bb3164da12-2 00:24:25.561 --> 00:24:27.519 electrical circuits and equipment. caaab14a-4293-49a7-8536-c66722ef6ae0-0 00:24:28.880 --> 00:24:32.966 Electrical switch gear regulate, protect and isolate a power caaab14a-4293-49a7-8536-c66722ef6ae0-1 00:24:32.966 --> 00:24:36.450 system with a variety of controls housed in a metal caaab14a-4293-49a7-8536-c66722ef6ae0-2 00:24:36.450 --> 00:24:37.120 enclosure. d3abca90-1b32-4bf6-b6b4-884c2f3f97d1-0 00:24:38.360 --> 00:24:41.998 It's a vital system in industries that experience d3abca90-1b32-4bf6-b6b4-884c2f3f97d1-1 00:24:41.998 --> 00:24:46.509 electrical faults or those that need to regularly de energize d3abca90-1b32-4bf6-b6b4-884c2f3f97d1-2 00:24:46.509 --> 00:24:50.511 equipment for vans, such as industrial environments or d3abca90-1b32-4bf6-b6b4-884c2f3f97d1-3 00:24:50.511 --> 00:24:52.040 electrical utilities. 6913c693-4f00-46b5-85be-9c4b0692051d-0 00:24:55.040 --> 00:24:58.099 Switch gear will typically contain fuses, switches, and 6913c693-4f00-46b5-85be-9c4b0692051d-1 00:24:58.099 --> 00:25:01.269 other power conductors, but circuit Breakers are the most 6913c693-4f00-46b5-85be-9c4b0692051d-2 00:25:01.269 --> 00:25:03.400 common component found in switch gear. 39f9cc28-81ac-47ba-80a7-08f7ff0b4e75-0 00:25:04.120 --> 00:25:07.378 During an electrical fault, a circuit breaker will sense the 39f9cc28-81ac-47ba-80a7-08f7ff0b4e75-1 00:25:07.378 --> 00:25:10.529 anomaly and interrupt the power flow, effectively limiting 39f9cc28-81ac-47ba-80a7-08f7ff0b4e75-2 00:25:10.529 --> 00:25:13.199 damage to the electrical system it's controlling. b88902bb-e1be-4236-96c4-9a1b5fcfb303-0 00:25:17.600 --> 00:25:21.241 A switchboard is an electrical enclosure also containing b88902bb-e1be-4236-96c4-9a1b5fcfb303-1 00:25:21.241 --> 00:25:25.009 circuit Breakers, switches, fuses and other apparatus that b88902bb-e1be-4236-96c4-9a1b5fcfb303-2 00:25:25.009 --> 00:25:29.161 is used to distribute electrical power within a building or some b88902bb-e1be-4236-96c4-9a1b5fcfb303-3 00:25:29.161 --> 00:25:30.120 other facility. 7ebaa4fc-aa78-4ea3-9f8f-80de6309ebf3-0 00:25:31.000 --> 00:25:34.882 Similar to the switch gear, the switchboard, they also include 7ebaa4fc-aa78-4ea3-9f8f-80de6309ebf3-1 00:25:34.882 --> 00:25:38.025 meters and relays and other electrical control and 7ebaa4fc-aa78-4ea3-9f8f-80de6309ebf3-2 00:25:38.025 --> 00:25:39.320 protection apparatus. 2a0cbc11-9559-4d04-9db5-519443d84e18-0 00:25:39.800 --> 00:25:44.250 And it may include panels or frames and have a or have 2a0cbc11-9559-4d04-9db5-519443d84e18-1 00:25:44.250 --> 00:25:46.840 control or monitoring functions. 63aa92b3-7d03-483c-9c26-1392a24071f3-0 00:25:48.720 --> 00:25:50.440 So what is the difference between the two? f356ebcd-e542-4eee-9ae5-aef37977bfb0-0 00:25:51.880 --> 00:25:54.560 For classification purposes, not much. b6879104-be18-417b-9d85-f6c24600c0ec-0 00:25:55.240 --> 00:25:58.383 Switch gear and switchboards both consist of a cabinet with b6879104-be18-417b-9d85-f6c24600c0ec-1 00:25:58.383 --> 00:26:01.578 multiple electrical apparatus and both perform an electrical b6879104-be18-417b-9d85-f6c24600c0ec-2 00:26:01.578 --> 00:26:03.360 control or distribution function. 04e53fdf-d677-4f2f-94ce-f2a21fa8f77e-0 00:26:04.440 --> 00:26:07.724 The differences are mainly and how they're used, their voltage 04e53fdf-d677-4f2f-94ce-f2a21fa8f77e-1 00:26:07.724 --> 00:26:10.800 ratings and how they're designed and how they're serviced. 67d2e2ce-ddb3-46aa-92ce-d9804bb51547-0 00:26:12.280 --> 00:26:15.691 Low voltage switch gear are mainly used to control, protect 67d2e2ce-ddb3-46aa-92ce-d9804bb51547-1 00:26:15.691 --> 00:26:19.274 and isolate electrical equipment or circuits in residential or 67d2e2ce-ddb3-46aa-92ce-d9804bb51547-2 00:26:19.274 --> 00:26:22.743 industrial settings and are often installed on the secondary 67d2e2ce-ddb3-46aa-92ce-d9804bb51547-3 00:26:22.743 --> 00:26:26.382 side of power entry Transformers where it supplies switchboards 67d2e2ce-ddb3-46aa-92ce-d9804bb51547-4 00:26:26.382 --> 00:26:27.520 and other equipment. 8a4cfdb1-9857-410e-a65d-2e349ee40e88-0 00:26:30.600 --> 00:26:34.020 Whereas switchboards are normally used to distribute 8a4cfdb1-9857-410e-a65d-2e349ee40e88-1 00:26:34.020 --> 00:26:38.086 electrical power in a building or structure like a residential 8a4cfdb1-9857-410e-a65d-2e349ee40e88-2 00:26:38.086 --> 00:26:41.894 or commercial setting, offices and retail stores, and some 8a4cfdb1-9857-410e-a65d-2e349ee40e88-3 00:26:41.894 --> 00:26:45.831 switchboards may even receive its power from upstream switch 8a4cfdb1-9857-410e-a65d-2e349ee40e88-4 00:26:45.831 --> 00:26:49.768 gear before feeding the power to electrical loads within the 8a4cfdb1-9857-410e-a65d-2e349ee40e88-5 00:26:49.768 --> 00:26:51.640 facility like lights or HVAC. ed8d04ad-ca92-48db-9564-e48cdea69a70-0 00:26:54.040 --> 00:26:58.789 Please make a note that medium and high voltage switch gear can ed8d04ad-ca92-48db-9564-e48cdea69a70-1 00:26:58.789 --> 00:27:03.242 be rated at over 300 kilovolts, while most switchboards are ed8d04ad-ca92-48db-9564-e48cdea69a70-2 00:27:03.242 --> 00:27:05.320 rated for 600 volts or less. ab50acf9-a9c7-44a1-b58e-a4d84fe9f4d6-0 00:27:06.040 --> 00:27:09.169 So we need to keep in mind the operating voltages for ab50acf9-a9c7-44a1-b58e-a4d84fe9f4d6-1 00:27:09.169 --> 00:27:10.560 classification purposes. 48ec77c9-6e08-4218-a60a-886b93ce51d1-0 00:27:20.800 --> 00:27:26.633 Next in line is the numerical controller of subheading 48ec77c9-6e08-4218-a60a-886b93ce51d1-1 00:27:26.633 --> 00:27:27.800 8537109130. 271228c8-22a0-4522-9047-ba166b8f5cde-0 00:27:29.280 --> 00:27:36.080 Computer numerical control is commonly referred to as CNCACNC. 8368328a-ea08-4e32-81ba-429c6aca8a7a-0 00:27:36.080 --> 00:27:39.616 Machine is the electrical controller of machines, 8368328a-ea08-4e32-81ba-429c6aca8a7a-1 00:27:39.616 --> 00:27:43.717 particularly machine tools by direct input of data from a 8368328a-ea08-4e32-81ba-429c6aca8a7a-2 00:27:43.717 --> 00:27:44.920 computer program. 95cc4183-855c-46c7-9064-f97ad557f4e2-0 00:27:45.840 --> 00:27:49.044 It is a special principal elements of a computer 95cc4183-855c-46c7-9064-f97ad557f4e2-1 00:27:49.044 --> 00:27:50.680 integrated manufacturing. d17da542-093d-45a7-9ddd-41629f6333d2-0 00:27:51.400 --> 00:27:55.280 ACNC is also essential to the operation of industrial robots. 227556c3-873e-40ba-9b85-ff2e69d7c05b-0 00:27:56.120 --> 00:28:00.742 CNC systems often receive their instructions from computer aided 227556c3-873e-40ba-9b85-ff2e69d7c05b-1 00:28:00.742 --> 00:28:01.880 design programs. b1b3964d-21aa-49f3-9c16-d4c42ac519f4-0 00:28:04.000 --> 00:28:07.564 Two types of CNC systems are point to point, in which a b1b3964d-21aa-49f3-9c16-d4c42ac519f4-1 00:28:07.564 --> 00:28:11.701 device is programmed to perform a series of motions with a fixed b1b3964d-21aa-49f3-9c16-d4c42ac519f4-2 00:28:11.701 --> 00:28:15.838 starting and stopping point, and the continuous path, in which a b1b3964d-21aa-49f3-9c16-d4c42ac519f4-3 00:28:15.838 --> 00:28:19.530 point to point program device has sufficient memory to be b1b3964d-21aa-49f3-9c16-d4c42ac519f4-4 00:28:19.530 --> 00:28:23.476 aware of its former actions and acts in accordance with those b1b3964d-21aa-49f3-9c16-d4c42ac519f4-5 00:28:23.476 --> 00:28:24.239 information. 8fd94808-2654-42cb-a1ec-4e19feb7052d-0 00:28:27.000 --> 00:28:31.172 You may also hear terms like multi Access control where some 8fd94808-2654-42cb-a1ec-4e19feb7052d-1 00:28:31.172 --> 00:28:35.481 CNC controllers will have the ability to move the machine tool 8fd94808-2654-42cb-a1ec-4e19feb7052d-2 00:28:35.481 --> 00:28:39.654 in multiple directions, commonly found in CNC controllers or 8fd94808-2654-42cb-a1ec-4e19feb7052d-3 00:28:39.654 --> 00:28:43.963 switches, contacts, meters, and internal printed circuit board 8fd94808-2654-42cb-a1ec-4e19feb7052d-4 00:28:43.963 --> 00:28:47.657 assemblies that contain instruction coding to control 8fd94808-2654-42cb-a1ec-4e19feb7052d-5 00:28:47.657 --> 00:28:51.624 the machines like a plasma cutter, a milling machine, and 8fd94808-2654-42cb-a1ec-4e19feb7052d-6 00:28:51.624 --> 00:28:52.240 robotics. 89ce34c1-5802-4c21-9843-0e673f704e18-0 00:28:53.280 --> 00:28:56.240 The CNC controller would likely be in close proximity to the 89ce34c1-5802-4c21-9843-0e673f704e18-1 00:28:56.240 --> 00:28:57.600 machine that is controlling. b9666d93-e4da-4721-97ea-a0c3114a29a1-0 00:28:58.640 --> 00:29:02.672 While the CNC machine certainly has programming, and you may b9666d93-e4da-4721-97ea-a0c3114a29a1-1 00:29:02.672 --> 00:29:07.035 feel compelled to classify it as a programmable controller, which b9666d93-e4da-4721-97ea-a0c3114a29a1-2 00:29:07.035 --> 00:29:11.398 occurs later on in heading 8537, the CNC machine is very specific b9666d93-e4da-4721-97ea-a0c3114a29a1-3 00:29:11.398 --> 00:29:14.440 in its function of controlling machine tools. ca71191a-e0ab-4719-ba9f-1f0bdf981660-0 00:29:18.800 --> 00:29:21.579 Here are a few examples of the types of machines that are ca71191a-e0ab-4719-ba9f-1f0bdf981660-1 00:29:21.579 --> 00:29:23.400 controlled by a numerical controller. f33a1b55-873d-4a53-8b7b-3e73558baacd-0 00:29:24.360 --> 00:29:28.056 There are 3D printing machines, CNC routers, embroidery f33a1b55-873d-4a53-8b7b-3e73558baacd-1 00:29:28.056 --> 00:29:30.960 machines, wood routers, and much much more. 81c6dc53-c671-4f31-a4d4-06fc9ef93307-0 00:29:32.480 --> 00:29:36.189 The explanatory notes describe numerical control apparatus as 81c6dc53-c671-4f31-a4d4-06fc9ef93307-1 00:29:36.189 --> 00:29:39.360 having a built in Automatic Data Processing machine. 2c0c0e19-8f9d-4865-b53f-b42395a2526f-0 00:29:40.000 --> 00:29:43.395 This has the potential of tripping us up, but for today's 2c0c0e19-8f9d-4865-b53f-b42395a2526f-1 00:29:43.395 --> 00:29:46.965 discussion, let's assume that we've done our homework and we 2c0c0e19-8f9d-4865-b53f-b42395a2526f-2 00:29:46.965 --> 00:29:50.653 know that numerical controller is not classified in heading AN 2c0c0e19-8f9d-4865-b53f-b42395a2526f-3 00:29:50.653 --> 00:29:52.000 8471 as an ADP machine. 541f83c2-8a97-4b10-b22d-c3eea3063f33-0 00:29:53.480 --> 00:29:57.379 Also, if we keep in mind the classification Section 16 is 541f83c2-8a97-4b10-b22d-c3eea3063f33-1 00:29:57.379 --> 00:30:01.615 based on function, we know that electrical control is provided 541f83c2-8a97-4b10-b22d-c3eea3063f33-2 00:30:01.615 --> 00:30:04.440 for in heading 8537 and not heading 8471. fc0d425b-f7af-4f58-9e10-d880edd1bdf3-0 00:30:11.040 --> 00:30:15.538 Continuing down the tariff page, we find the provision for panel fc0d425b-f7af-4f58-9e10-d880edd1bdf3-1 00:30:15.538 --> 00:30:17.200 and distribution boards. 5521e400-914b-4720-8f47-7a8400bed2f7-0 00:30:18.160 --> 00:30:21.104 The National Electric Code provides us with a great 5521e400-914b-4720-8f47-7a8400bed2f7-1 00:30:21.104 --> 00:30:24.274 definition of an electrical panel and you can give some 5521e400-914b-4720-8f47-7a8400bed2f7-2 00:30:24.274 --> 00:30:25.520 examples of their use. 8d8af983-8dfd-44ee-a425-d80dd3bd53df-0 00:30:27.160 --> 00:30:30.545 These electrical panels are common and in many manufacturing 8d8af983-8dfd-44ee-a425-d80dd3bd53df-1 00:30:30.545 --> 00:30:33.320 facilities as well as offices and even your home. 743f4073-5e97-4c8d-9288-dba00f37e61d-0 00:30:34.480 --> 00:30:37.970 They're used to distribute power throughout the building, usually 743f4073-5e97-4c8d-9288-dba00f37e61d-1 00:30:37.970 --> 00:30:40.880 to control lights, outlets, and environmental systems. 1f498380-1874-4e75-863e-5de5fd35dd74-0 00:30:45.920 --> 00:30:50.124 As an example, here is a diagram of an electrical panel placed in 1f498380-1874-4e75-863e-5de5fd35dd74-1 00:30:50.124 --> 00:30:52.800 line with a previous switchboard picture. 42a354c3-69da-438b-8708-1bdabacef735-0 00:30:54.920 --> 00:30:59.090 You can see the power enters the building is first met by the 42a354c3-69da-438b-8708-1bdabacef735-1 00:30:59.090 --> 00:31:03.192 primary switch, then it's met by a transformer, and then the 42a354c3-69da-438b-8708-1bdabacef735-2 00:31:03.192 --> 00:31:04.000 switchboard. 2cf7b496-6c90-49a3-a0f3-3a2faf15f0cf-0 00:31:04.720 --> 00:31:08.971 The switchboard is distributing power to the machinery, let's 2cf7b496-6c90-49a3-a0f3-3a2faf15f0cf-1 00:31:08.971 --> 00:31:13.222 say some type of grinder or a mixer, a material movement like 2cf7b496-6c90-49a3-a0f3-3a2faf15f0cf-2 00:31:13.222 --> 00:31:17.337 belts and motors and other medium voltage machinery, but it 2cf7b496-6c90-49a3-a0f3-3a2faf15f0cf-3 00:31:17.337 --> 00:31:20.080 also supplies power to the panel board. 9f550776-ce50-4a34-9312-7d7cf0bddd06-0 00:31:25.160 --> 00:31:28.860 One of the most common subheadings in 8537 involves 9f550776-ce50-4a34-9312-7d7cf0bddd06-1 00:31:28.860 --> 00:31:30.640 programmable controllers. 42ff477f-5b28-410a-b59a-20246d4c87f9-0 00:31:31.520 --> 00:31:35.060 Programmable controllers usually involve printed circuit board 42ff477f-5b28-410a-b59a-20246d4c87f9-1 00:31:35.060 --> 00:31:38.263 assemblies that have digital processing capabilities and 42ff477f-5b28-410a-b59a-20246d4c87f9-2 00:31:38.263 --> 00:31:41.859 outputs for intelligent control of the machine or machines that 42ff477f-5b28-410a-b59a-20246d4c87f9-3 00:31:41.859 --> 00:31:43.040 they are controlling. ed6f1cea-67f5-4ed2-947e-8e39af0a0d64-0 00:31:44.640 --> 00:31:48.622 One type of programmable controller is the programmable ed6f1cea-67f5-4ed2-947e-8e39af0a0d64-1 00:31:48.622 --> 00:31:50.400 logic controller, or PLC. 0f9fbe0d-bf8a-44eb-a6cd-2d378d86cbba-0 00:31:51.800 --> 00:31:55.788 PLCS are specialized industrial computers with various inputs 0f9fbe0d-bf8a-44eb-a6cd-2d378d86cbba-1 00:31:55.788 --> 00:31:56.560 and outputs. bd498cdd-6270-4a7a-b7fe-d031d094ba20-0 00:31:57.000 --> 00:32:00.218 They're used to control and monitor industrial equipment bd498cdd-6270-4a7a-b7fe-d031d094ba20-1 00:32:00.218 --> 00:32:01.800 based on custom programming. 19cb4203-187b-4b60-a308-75e85a2f61df-0 00:32:03.560 --> 00:32:07.785 PLCS come in many different sizes and form factors and are 19cb4203-187b-4b60-a308-75e85a2f61df-1 00:32:07.785 --> 00:32:11.509 designed to reliably operate under harsh industrial 19cb4203-187b-4b60-a308-75e85a2f61df-2 00:32:11.509 --> 00:32:12.440 environments. d95bf27c-1621-41aa-87b6-548f82d5df9c-0 00:32:15.160 --> 00:32:18.486 Some are small enough to fit in your pocket, while others are d95bf27c-1621-41aa-87b6-548f82d5df9c-1 00:32:18.486 --> 00:32:21.437 large enough to require their own heavy duty racks and d95bf27c-1621-41aa-87b6-548f82d5df9c-2 00:32:21.437 --> 00:32:21.920 cabinets. 13152329-54c5-475e-bbc3-b99b56cf413c-0 00:32:22.920 --> 00:32:27.041 Many PLCS are modular with inputs and output modules, and 13152329-54c5-475e-bbc3-b99b56cf413c-1 00:32:27.041 --> 00:32:30.523 can be customized with additional backplanes and 13152329-54c5-475e-bbc3-b99b56cf413c-2 00:32:30.523 --> 00:32:33.934 functional modules such as analog input, output 13152329-54c5-475e-bbc3-b99b56cf413c-3 00:32:33.934 --> 00:32:38.269 communication modules, display modules, whatever it needs to 13152329-54c5-475e-bbc3-b99b56cf413c-4 00:32:38.269 --> 00:32:41.680 for different types of industrial applications. 7392d3e9-2133-4f85-ac04-0e7286321f61-0 00:32:44.320 --> 00:32:48.040 But is APLC the same thing as a programmable controller? 285b110e-7cd6-4f8c-9870-ddc951e18aad-0 00:32:49.200 --> 00:32:50.960 In reality, no. de481928-3f78-4779-9bf5-05b6ba97f7b1-0 00:32:51.480 --> 00:32:54.806 The PLC is a type of programmable controller, but for de481928-3f78-4779-9bf5-05b6ba97f7b1-1 00:32:54.806 --> 00:32:58.440 tariff purposes, there's no reason to distinguish the two. 868fbf0b-f234-494f-9b75-62fd85b78e7c-0 00:32:59.080 --> 00:33:02.522 But since we're supposed to be focusing on industrial controls 868fbf0b-f234-494f-9b75-62fd85b78e7c-1 00:33:02.522 --> 00:33:05.582 and not just any type of electrical control, the PLC is 868fbf0b-f234-494f-9b75-62fd85b78e7c-2 00:33:05.582 --> 00:33:07.440 what we like to talk about today. 02ca437b-9325-47b5-bddf-657384fd4159-0 00:33:09.920 --> 00:33:13.626 The explanatory notes make a specific point to describe what 02ca437b-9325-47b5-bddf-657384fd4159-1 00:33:13.626 --> 00:33:16.360 is required to be a programmable controller. 07f0b2be-b384-474f-a8e3-1600e163f8d1-0 00:33:19.480 --> 00:33:23.423 This heading also covers programmable controllers, which 07f0b2be-b384-474f-a8e3-1600e163f8d1-1 00:33:23.423 --> 00:33:27.298 are digital apparatus using programmable memory for the 07f0b2be-b384-474f-a8e3-1600e163f8d1-2 00:33:27.298 --> 00:33:31.450 storage of instructions for implementing specific functions 07f0b2be-b384-474f-a8e3-1600e163f8d1-3 00:33:31.450 --> 00:33:35.532 such as logic, sequencing, timing, counting, arithmetic to 07f0b2be-b384-474f-a8e3-1600e163f8d1-4 00:33:35.532 --> 00:33:39.960 control through various digital or analog input output modules, 07f0b2be-b384-474f-a8e3-1600e163f8d1-5 00:33:39.960 --> 00:33:41.760 various types of machines. 427614a9-d790-4572-adad-83315566a509-0 00:33:42.960 --> 00:33:45.600 What the explanatory notes are describing our PLCS. 3887ee1c-1411-41bf-b201-43b285c77e95-0 00:33:46.040 --> 00:33:49.661 The explanatory notes are making this distinction, but really 3887ee1c-1411-41bf-b201-43b285c77e95-1 00:33:49.661 --> 00:33:53.166 there's countless electrical controllers that would satisfy 3887ee1c-1411-41bf-b201-43b285c77e95-2 00:33:53.166 --> 00:33:56.086 the heading requirements of 8537, but they're not 3887ee1c-1411-41bf-b201-43b285c77e95-3 00:33:56.086 --> 00:33:57.080 necessarily APLC. 50de331c-9966-4fa8-b219-f951a764fdf4-0 00:33:58.640 --> 00:34:01.746 So this can get confusing because the ENS also talk about 50de331c-9966-4fa8-b219-f951a764fdf4-1 00:34:01.746 --> 00:34:04.960 programmable switchboards that go into domestic appliances. fdcdb126-ce8f-4a3e-8d67-8c8dec8ba5a6-0 00:34:05.520 --> 00:34:09.205 So perhaps the ENS are not effectively keeping up with fdcdb126-ce8f-4a3e-8d67-8c8dec8ba5a6-1 00:34:09.205 --> 00:34:13.360 technology or maybe it's just that there's more than one type fdcdb126-ce8f-4a3e-8d67-8c8dec8ba5a6-2 00:34:13.360 --> 00:34:17.582 of programmable controller that could be classified in heading fdcdb126-ce8f-4a3e-8d67-8c8dec8ba5a6-3 00:34:17.582 --> 00:34:18.320 8537109160. cf7f98fa-7355-49f3-95c5-cb9a184d9ecd-0 00:34:19.920 --> 00:34:24.722 If you do a quick search in Cross, you'll easily find a long cf7f98fa-7355-49f3-95c5-cb9a184d9ecd-1 00:34:24.722 --> 00:34:27.400 list of binding rulings for CBPS. 5fc01f50-de7b-4c1e-9611-53ca61bb88d0-0 00:34:27.400 --> 00:34:31.535 Position has been that if the controller meets the heading 5fc01f50-de7b-4c1e-9611-53ca61bb88d0-1 00:34:31.535 --> 00:34:35.460 requirement and is a digital device having programmable 5fc01f50-de7b-4c1e-9611-53ca61bb88d0-2 00:34:35.460 --> 00:34:39.596 memory, then it is classified as a programmable controller 5fc01f50-de7b-4c1e-9611-53ca61bb88d0-3 00:34:39.596 --> 00:34:42.399 regardless of whether it's APLC or not. f2e30e01-bceb-489e-9c0d-57a95e0316d8-0 00:34:43.920 --> 00:34:46.834 But since we're supposed to be talking about industrial f2e30e01-bceb-489e-9c0d-57a95e0316d8-1 00:34:46.834 --> 00:34:49.280 controls, let's focus on the PLC for a moment. f67fce94-54bf-4d60-8a9e-791d246c0997-0 00:34:51.240 --> 00:34:56.000 In general terms, APLC consists of the CPU or Central processing f67fce94-54bf-4d60-8a9e-791d246c0997-1 00:34:56.000 --> 00:35:00.760 unit, input and output modules, a power supply, and programming. 954d44d9-8a34-4d60-b5af-f5a253c8c537-0 00:35:01.560 --> 00:35:04.952 Larger and more complex configurations can also have 954d44d9-8a34-4d60-b5af-f5a253c8c537-1 00:35:04.952 --> 00:35:08.600 communication modules or specialized modules that can be 954d44d9-8a34-4d60-b5af-f5a253c8c537-2 00:35:08.600 --> 00:35:10.840 performing all sorts of functions. 7caa5b19-ea3d-4484-a51d-adbaeb201787-0 00:35:13.640 --> 00:35:15.800 The CPU is the brain of the PLC. e6f9b0ee-c40b-43dc-b4a4-ac098223c1b9-0 00:35:16.440 --> 00:35:19.615 It executes control instructions, it processes data e6f9b0ee-c40b-43dc-b4a4-ac098223c1b9-1 00:35:19.615 --> 00:35:22.120 and communicates with the other modules. 31a56aaf-0993-404b-8411-9596e25d1887-0 00:35:22.680 --> 00:35:26.127 It's responsible for interpreting inputs, running the 31a56aaf-0993-404b-8411-9596e25d1887-1 00:35:26.127 --> 00:35:29.000 control program, and sending output signals. 21131b28-cbb9-4375-8d63-9c289754e71c-0 00:35:30.840 --> 00:35:34.579 The input modules receive the information from field devices 21131b28-cbb9-4375-8d63-9c289754e71c-1 00:35:34.579 --> 00:35:38.196 like sensors, and based on programming, they can allow the 21131b28-cbb9-4375-8d63-9c289754e71c-2 00:35:38.196 --> 00:35:42.120 output modules to actuate other devices like motors and valves. 65d6131f-2443-4b4a-a83b-0beeed2150f4-0 00:35:42.720 --> 00:35:46.406 Input modules convert various signals into a format that the 65d6131f-2443-4b4a-a83b-0beeed2150f4-1 00:35:46.406 --> 00:35:50.093 CPU can understand, while the output modules convert the CPU 65d6131f-2443-4b4a-a83b-0beeed2150f4-2 00:35:50.093 --> 00:35:53.720 instructions into physical actions such as control signals. a868364c-2578-48a6-8b1a-5ffedb0f2d61-0 00:35:56.240 --> 00:35:59.774 The power supply unit provides the necessary electrical power a868364c-2578-48a6-8b1a-5ffedb0f2d61-1 00:35:59.774 --> 00:36:00.800 to the TLC system. befc6c1a-e940-445f-8f5d-6217a54d25b2-0 00:36:01.440 --> 00:36:04.263 It typically converts alternating current from the befc6c1a-e940-445f-8f5d-6217a54d25b2-1 00:36:04.263 --> 00:36:07.640 main supply to a direct current required by the PLC modules. f7a3eeb6-c7aa-4292-b223-bb0595e0caea-0 00:36:10.120 --> 00:36:14.073 Lastly, PLCS are programmed using dedicated devices or f7a3eeb6-c7aa-4292-b223-bb0595e0caea-1 00:36:14.073 --> 00:36:14.720 software. 7b712fc8-6e19-4d60-9de1-23df1dbd734d-0 00:36:15.800 --> 00:36:20.426 This programming This programming can range from 7b712fc8-6e19-4d60-9de1-23df1dbd734d-1 00:36:20.426 --> 00:36:26.468 instructions that are simple to complex algorithms depending on 7b712fc8-6e19-4d60-9de1-23df1dbd734d-2 00:36:26.468 --> 00:36:28.640 the applications needs. 7d7c3945-4b21-476e-8a36-aa68841522a3-0 00:36:29.440 --> 00:36:32.901 As you can see here, this PLC has many modules and are light 7d7c3945-4b21-476e-8a36-aa68841522a3-1 00:36:32.901 --> 00:36:36.306 and is likely mounted on a rail inside of an enclosure or a 7d7c3945-4b21-476e-8a36-aa68841522a3-2 00:36:36.306 --> 00:36:36.760 cabinet. f29efe7f-949e-4e29-9e8e-42d97a549b4d-0 00:36:37.800 --> 00:36:42.922 Just from glancing here, we can see from left to right a power f29efe7f-949e-4e29-9e8e-42d97a549b4d-1 00:36:42.922 --> 00:36:47.556 supply module, a combined CPU and communications module, f29efe7f-949e-4e29-9e8e-42d97a549b4d-2 00:36:47.556 --> 00:36:52.759 relayed output module, ocean and speciality modules, digital IO f29efe7f-949e-4e29-9e8e-42d97a549b4d-3 00:36:52.759 --> 00:36:55.280 modules, and analog IO modules. 2e8a3e40-ac3b-40d2-bde0-05628e177e0c-0 00:36:56.600 --> 00:37:00.549 If this entire system is presented together at entry, we 2e8a3e40-ac3b-40d2-bde0-05628e177e0c-1 00:37:00.549 --> 00:37:04.707 would classify the whole thing as a programmable controller 2e8a3e40-ac3b-40d2-bde0-05628e177e0c-2 00:37:04.707 --> 00:37:06.440 under subedit 8537109160. 46ff5c2c-9abf-4d2e-ad80-9f97363b277c-0 00:37:08.440 --> 00:37:11.614 If the individual modules are entered separately, we would 46ff5c2c-9abf-4d2e-ad80-9f97363b277c-1 00:37:11.614 --> 00:37:15.058 classify them according to their function, not necessarily as a 46ff5c2c-9abf-4d2e-ad80-9f97363b277c-2 00:37:15.058 --> 00:37:15.920 part of the PLC. 022e06df-29e0-4f5b-9c0d-55fd078cce47-0 00:37:16.840 --> 00:37:22.496 For example, if the CPU module was imported by itself, we would 022e06df-29e0-4f5b-9c0d-55fd078cce47-1 00:37:22.496 --> 00:37:26.120 classify it under submitting 8537109160. ef70202a-4082-44bb-b741-9bbebecfc2a5-0 00:37:27.840 --> 00:37:32.198 But circling back to all the webinars and training that we've ef70202a-4082-44bb-b741-9bbebecfc2a5-1 00:37:32.198 --> 00:37:36.487 provided that cover articles of Section 16 in the tariff, we ef70202a-4082-44bb-b741-9bbebecfc2a5-2 00:37:36.487 --> 00:37:40.986 know that Note 2 to Section 16 drives our approach to parts and ef70202a-4082-44bb-b741-9bbebecfc2a5-3 00:37:40.986 --> 00:37:41.759 components. 54e2d9d9-02d5-4ff4-be6c-2d77964ddb30-0 00:37:42.640 --> 00:37:47.837 So if the power supply module is imported on its own, it's 54e2d9d9-02d5-4ff4-be6c-2d77964ddb30-1 00:37:47.837 --> 00:37:53.122 classified as a power supply and heading 85 O 4, the output 54e2d9d9-02d5-4ff4-be6c-2d77964ddb30-2 00:37:53.122 --> 00:37:58.231 module having relayed output channels will likely satisfy 54e2d9d9-02d5-4ff4-be6c-2d77964ddb30-3 00:37:58.231 --> 00:38:03.340 heading 8537 and we would classify it there, but not as a 54e2d9d9-02d5-4ff4-be6c-2d77964ddb30-4 00:38:03.340 --> 00:38:06.599 PLC but under subheading 8537109170. 516a34be-1cf5-4eb1-9c7a-930687a87c7a-0 00:38:08.520 --> 00:38:09.560 But an input module. 733f2a5e-cfb4-4ec1-9abd-5adb0e8f72b2-0 00:38:10.560 --> 00:38:13.442 Well, input modules don't have relayed outputs, and they don't 733f2a5e-cfb4-4ec1-9abd-5adb0e8f72b2-1 00:38:13.442 --> 00:38:16.280 control external machines and devices like output modules do. d7e6123e-5922-4c67-9d22-550da6431afe-0 00:38:17.040 --> 00:38:21.027 We probably classify the input module as a part and heading d7e6123e-5922-4c67-9d22-550da6431afe-1 00:38:21.027 --> 00:38:21.360 8538. 602aef87-cf38-40cc-aba6-8d91de8df3f8-0 00:38:23.000 --> 00:38:24.560 What about the communication module? efcd57ab-cd2d-4722-953e-b0e37ad98d34-0 00:38:26.040 --> 00:38:28.848 These devices connect programmable controllers to the efcd57ab-cd2d-4722-953e-b0e37ad98d34-1 00:38:28.848 --> 00:38:29.680 factory network. 7d8cff93-faaf-42f5-8b95-8436cfdd6829-0 00:38:30.240 --> 00:38:30.760 Again, no. b78ae216-84ba-41bd-9014-0bcfd5b5f3e2-0 00:38:30.760 --> 00:38:34.712 T directs us to classify by function, and they would likely b78ae216-84ba-41bd-9014-0bcfd5b5f3e2-1 00:38:34.712 --> 00:38:37.480 satisfy the requirements of heading 8517. 47dfe86f-1b30-4a15-8dc2-99853233130b-0 00:38:40.360 --> 00:38:43.827 All of this comes about because Note 2 directs us to classify 47dfe86f-1b30-4a15-8dc2-99853233130b-1 00:38:43.827 --> 00:38:46.680 articles in their own provisions when appropriate. abcc25bc-eb10-4f52-86f0-198afa8570ac-0 00:38:50.080 --> 00:38:54.268 While the PLC is the type of programmable controller, there abcc25bc-eb10-4f52-86f0-198afa8570ac-1 00:38:54.268 --> 00:38:58.596 are many other types of machines that also perform electrical abcc25bc-eb10-4f52-86f0-198afa8570ac-2 00:38:58.596 --> 00:39:02.435 control, switching and distribution and they would not abcc25bc-eb10-4f52-86f0-198afa8570ac-3 00:39:02.435 --> 00:39:04.600 be formally identified as Aplc. 42a602cd-1570-4db9-9e10-4946a23f9cf7-0 00:39:05.880 --> 00:39:08.724 They don't have to be some complex multi cap cabinet 42a602cd-1570-4db9-9e10-4946a23f9cf7-1 00:39:08.724 --> 00:39:12.160 machine with miles of wires and hundreds of electrical devices. f909df2d-39a6-4cef-832e-09c206fbe1ed-0 00:39:12.600 --> 00:39:15.793 They could be simple single board computers that have f909df2d-39a6-4cef-832e-09c206fbe1ed-1 00:39:15.793 --> 00:39:18.040 relayed outputs to control something. 5541e036-085f-4762-9cb4-eaf2e2b72ac7-0 00:39:18.040 --> 00:39:18.760 Some machine. 80c6fd7a-b694-4fba-9d84-2d46f4f8d935-0 00:39:20.360 --> 00:39:24.152 For example, if you brew beer at home and have an electrical 80c6fd7a-b694-4fba-9d84-2d46f4f8d935-1 00:39:24.152 --> 00:39:27.944 system, you could be using APID controller or even something 80c6fd7a-b694-4fba-9d84-2d46f4f8d935-2 00:39:27.944 --> 00:39:31.861 like this, little control at the top right, a basic electrical 80c6fd7a-b694-4fba-9d84-2d46f4f8d935-3 00:39:31.861 --> 00:39:35.405 controller that turns the heating coil and recirculation 80c6fd7a-b694-4fba-9d84-2d46f4f8d935-4 00:39:35.405 --> 00:39:36.400 pump on and off. 70a11019-868c-4b37-b777-a9a4dd71a45c-0 00:39:39.160 --> 00:39:42.680 Or they can be very complex systems. 591f14e7-0f28-4ca0-a3cd-d4b8716efde1-0 00:39:43.280 --> 00:39:45.600 And when I say complex, I mean the Sky's the limit. 79515b84-6433-4e60-bc85-69538d862588-0 00:39:46.200 --> 00:39:46.520 Today. 50543cf5-f9f9-47c8-895d-306912e18688-0 00:39:46.520 --> 00:39:50.211 We won't get into what's called SCADA, and that stands for 50543cf5-f9f9-47c8-895d-306912e18688-1 00:39:50.211 --> 00:39:52.840 Supervisory Control and Data acquisition. 10a13a0b-f82d-471b-911c-e9879ac51db9-0 00:39:54.560 --> 00:39:57.712 But think about public utility control rooms, where system 10a13a0b-f82d-471b-911c-e9879ac51db9-1 00:39:57.712 --> 00:40:00.919 operators are controlling the electrical grid from a remote 10a13a0b-f82d-471b-911c-e9879ac51db9-2 00:40:00.919 --> 00:40:01.400 location. 6065a7a3-be19-4da9-aad8-22ade9f7510e-0 00:40:01.880 --> 00:40:04.679 And each connection can be monitored and switched and 6065a7a3-be19-4da9-aad8-22ade9f7510e-1 00:40:04.679 --> 00:40:06.960 rerouted to accommodate electrical demands. 261f9fec-8351-4971-9341-c3753429eb92-0 00:40:08.560 --> 00:40:11.835 Keeping our focus on industrial controls, These industrial 261f9fec-8351-4971-9341-c3753429eb92-1 00:40:11.835 --> 00:40:15.332 controllers can be distributed throughout the facility so that 261f9fec-8351-4971-9341-c3753429eb92-2 00:40:15.332 --> 00:40:18.773 you have a main controller in one location that we would call 261f9fec-8351-4971-9341-c3753429eb92-3 00:40:18.773 --> 00:40:21.882 a host controller and then remote input output racks at 261f9fec-8351-4971-9341-c3753429eb92-4 00:40:21.882 --> 00:40:24.880 various locations throughout the manufacturing plant. fc520955-8339-478e-9112-dd621d458a43-0 00:40:25.400 --> 00:40:29.329 And sometimes the controller will have a graphical display or fc520955-8339-478e-9112-dd621d458a43-1 00:40:29.329 --> 00:40:30.280 a touch screen. 94472253-17e5-4c83-8145-aeef6402cfc6-0 00:40:31.760 --> 00:40:35.293 But don't confuse a programmable controller with a human machine 94472253-17e5-4c83-8145-aeef6402cfc6-1 00:40:35.293 --> 00:40:37.360 interface, which we'll get into next. e5f623f8-4fb7-404c-806f-5ebc29cc1a9d-0 00:40:40.360 --> 00:40:43.366 Before we move on, I'd like to clarify an essential point in e5f623f8-4fb7-404c-806f-5ebc29cc1a9d-1 00:40:43.366 --> 00:40:45.240 classifying this type of merchandise. caf8fd40-8eb1-496a-b7e7-2e6f7e61eec9-0 00:40:46.280 --> 00:40:50.365 Grabbable controller, regardless of any display capabilities, caf8fd40-8eb1-496a-b7e7-2e6f7e61eec9-1 00:40:50.365 --> 00:40:54.385 must still meet the heading requirements and the explanatory caf8fd40-8eb1-496a-b7e7-2e6f7e61eec9-2 00:40:54.385 --> 00:40:55.440 node provisions. d50e7ad3-4f24-4f5a-a36e-c1ad8b9e30a2-0 00:40:56.120 --> 00:41:00.263 If you don't have two or more apparatus of headings 8535 or d50e7ad3-4f24-4f5a-a36e-c1ad8b9e30a2-1 00:41:00.263 --> 00:41:02.680 8536, it can't be classified here. 45b3b913-4332-4b2a-9c71-4e686af9b6b5-0 00:41:03.200 --> 00:41:06.987 If the principal function is not electrical control, it can't be 45b3b913-4332-4b2a-9c71-4e686af9b6b5-1 00:41:06.987 --> 00:41:07.920 classified here. a5d2f0dd-985e-4bfb-9080-206790852405-0 00:41:13.040 --> 00:41:15.360 We now find ourselves at the bottom of subheading. f76195f2-34c5-4415-b1eb-42fe4352297e-0 00:41:15.360 --> 00:41:20.036 85371091 is somewhat of a basket provision for electrical control f76195f2-34c5-4415-b1eb-42fe4352297e-1 00:41:20.036 --> 00:41:24.074 and distribution machines, although I wouldn't call it a f76195f2-34c5-4415-b1eb-42fe4352297e-2 00:41:24.074 --> 00:41:28.254 true basket provision because the route to get here passes f76195f2-34c5-4415-b1eb-42fe4352297e-3 00:41:28.254 --> 00:41:31.938 through some very specific machines and the heading f76195f2-34c5-4415-b1eb-42fe4352297e-4 00:41:31.938 --> 00:41:34.560 requirements are also very specific. 39cbfe0b-fd66-4ce3-9581-18d41c15aea1-0 00:41:37.520 --> 00:41:41.290 Still keeping in mind that we're discussing industrial control 39cbfe0b-fd66-4ce3-9581-18d41c15aea1-1 00:41:41.290 --> 00:41:44.522 equipment that's not an MCC or switch gear or APLC or 39cbfe0b-fd66-4ce3-9581-18d41c15aea1-2 00:41:44.522 --> 00:41:48.112 distribution boards, we will find other devices or machines 39cbfe0b-fd66-4ce3-9581-18d41c15aea1-3 00:41:48.112 --> 00:41:51.464 that have your principal function of electrical control 39cbfe0b-fd66-4ce3-9581-18d41c15aea1-4 00:41:51.464 --> 00:41:53.080 or electrical distribution. a97dde0a-98c4-4fbb-ba82-15a25b467c70-0 00:41:53.680 --> 00:41:55.200 Here are just a few examples. b86e3c84-5a8b-4c09-9d81-69c9d1d20c79-0 00:41:56.800 --> 00:42:01.070 PLC output modules which we talked about, relay print, b86e3c84-5a8b-4c09-9d81-69c9d1d20c79-1 00:42:01.070 --> 00:42:05.807 circuit board assemblies, MCC compartments and human machine b86e3c84-5a8b-4c09-9d81-69c9d1d20c79-2 00:42:05.807 --> 00:42:07.360 interfaces or HM IS. 60b63d46-53d7-47b1-87f0-352e62931bb2-0 00:42:08.640 --> 00:42:10.160 The possibilities are endless. cf07fc4f-1897-41ca-a549-86aba06856e6-0 00:42:10.960 --> 00:42:16.056 Take for example the MCC bucket or compartment, a metal frame cf07fc4f-1897-41ca-a549-86aba06856e6-1 00:42:16.056 --> 00:42:20.906 with a contactor, a disconnect switch, terminal blocks and cf07fc4f-1897-41ca-a549-86aba06856e6-2 00:42:20.906 --> 00:42:21.399 fuses. f6e86337-8c79-45b8-bd50-8debeb2e129e-0 00:42:22.280 --> 00:42:25.807 It makes perfect sense that it's classified in subheading f6e86337-8c79-45b8-bd50-8debeb2e129e-1 00:42:25.807 --> 00:42:29.760 8537109170 because it meets the heading requirements directly as f6e86337-8c79-45b8-bd50-8debeb2e129e-2 00:42:29.760 --> 00:42:32.983 it incorporates 2 or more electrical apparatus, it's f6e86337-8c79-45b8-bd50-8debeb2e129e-3 00:42:32.983 --> 00:42:36.389 mounted on a frame, and it's performing the function of f6e86337-8c79-45b8-bd50-8debeb2e129e-4 00:42:36.389 --> 00:42:38.640 electrical control and distribution. 0e6596f8-a63c-4546-b49b-4e3aba504cfd-0 00:42:40.320 --> 00:42:44.007 I'm not certain if an MCC bucket is ever imported on its own, but 0e6596f8-a63c-4546-b49b-4e3aba504cfd-1 00:42:44.007 --> 00:42:47.080 it makes for a great example for my presentation here. 84120b13-28a1-45e3-9e5c-363f6b4bbda9-0 00:42:48.960 --> 00:42:52.768 Last on our list, what we're going to discuss today are what 84120b13-28a1-45e3-9e5c-363f6b4bbda9-1 00:42:52.768 --> 00:42:55.640 we call HM is of the human Machine interface. 192b12a8-8551-4470-8012-ab3661933280-0 00:43:00.120 --> 00:43:03.759 HMI are one of the more common industrial control related 192b12a8-8551-4470-8012-ab3661933280-1 00:43:03.759 --> 00:43:06.960 machines that are classified here in heading 8537. 27729a48-b03c-4b9a-bac4-b25c6dd512bf-0 00:43:07.640 --> 00:43:10.737 They can take a variety of forms, including those having 27729a48-b03c-4b9a-bac4-b25c6dd512bf-1 00:43:10.737 --> 00:43:14.053 graphical user interface that functions like a computer type 27729a48-b03c-4b9a-bac4-b25c6dd512bf-2 00:43:14.053 --> 00:43:16.988 controller, and it may have touch screens or physical 27729a48-b03c-4b9a-bac4-b25c6dd512bf-3 00:43:16.988 --> 00:43:19.760 control panels with buttons and displays, or both. 9b79037a-a51c-41fd-9b46-4228ff7954e2-0 00:43:20.800 --> 00:43:23.877 They're used to present data and system conditions to the 9b79037a-a51c-41fd-9b46-4228ff7954e2-1 00:43:23.877 --> 00:43:27.326 operator and allow the operator to input commands and set points 9b79037a-a51c-41fd-9b46-4228ff7954e2-2 00:43:27.326 --> 00:43:30.510 and the show alarms and other information, or even give the 9b79037a-a51c-41fd-9b46-4228ff7954e2-3 00:43:30.510 --> 00:43:33.800 operator control to turn the machines and devices on and off. c649265f-63d5-4105-b113-76e85d90cd8a-0 00:43:34.960 --> 00:43:38.616 Hmis are often connected to programmable controllers, where c649265f-63d5-4105-b113-76e85d90cd8a-1 00:43:38.616 --> 00:43:42.272 the POC is responsible for controlling the process based on c649265f-63d5-4105-b113-76e85d90cd8a-2 00:43:42.272 --> 00:43:45.320 user input from the HMI and sensors in the field. 2b66e3b3-9b25-4c75-8002-d793a4a711b1-0 00:43:47.160 --> 00:43:50.413 The HMI simply represents the information to the operator and 2b66e3b3-9b25-4c75-8002-d793a4a711b1-1 00:43:50.413 --> 00:43:53.615 allows them to input commands which are then sent to the PLC 2b66e3b3-9b25-4c75-8002-d793a4a711b1-2 00:43:53.615 --> 00:43:54.560 to be implemented. ee54e84c-9dec-419a-9685-ca9a121f08ed-0 00:43:56.440 --> 00:44:00.320 As we just said, many HMI allow for physical control over the ee54e84c-9dec-419a-9685-ca9a121f08ed-1 00:44:00.320 --> 00:44:01.760 system it's monitoring. 426efac1-0a63-421c-bc8a-6f0588262e15-0 00:44:02.960 --> 00:44:06.334 Let's say for example that you want to open a valve to release 426efac1-0a63-421c-bc8a-6f0588262e15-1 00:44:06.334 --> 00:44:09.120 some pressure or turn water on to clean out a tank. 86cf1832-bab5-4527-a5b0-32aff57cb151-0 00:44:10.400 --> 00:44:13.901 The HMI in this example would be mounted to an industrial control 86cf1832-bab5-4527-a5b0-32aff57cb151-1 00:44:13.901 --> 00:44:17.350 cabinet on the factory floor and the technician would select and 86cf1832-bab5-4527-a5b0-32aff57cb151-2 00:44:17.350 --> 00:44:20.640 press the appropriate button to electrically open the valves. c39d1450-7539-4e1d-afdc-df15e8f7c57a-0 00:44:21.760 --> 00:44:24.240 This really is the epitome of electrical control. 22d4d9e8-d648-4fc2-aafd-0b3de4e25d35-0 00:44:26.440 --> 00:44:30.169 HMI also provide for system indication control like alarm 22d4d9e8-d648-4fc2-aafd-0b3de4e25d35-1 00:44:30.169 --> 00:44:31.520 indicator shown here. 757954b2-c7fc-41c2-aa31-b2587bfbc74f-0 00:44:32.920 --> 00:44:35.676 The operator could view and clear the alarm condition and 757954b2-c7fc-41c2-aa31-b2587bfbc74f-1 00:44:35.676 --> 00:44:36.960 make changes to the system. 2f7319f4-ca03-4edd-a893-424e6948d6f9-0 00:44:38.280 --> 00:44:41.757 But Please remember that just because you're classifying an 2f7319f4-ca03-4edd-a893-424e6948d6f9-1 00:44:41.757 --> 00:44:45.350 HMI doesn't automatically mean you can classify it in heading 2f7319f4-ca03-4edd-a893-424e6948d6f9-2 00:44:45.350 --> 00:44:45.640 8537. 57d39574-ee51-442c-bde1-7e8cc49548b2-0 00:44:46.680 --> 00:44:49.244 You still need to verify that all the requirements are met, 57d39574-ee51-442c-bde1-7e8cc49548b2-1 00:44:49.244 --> 00:44:51.895 the most important of which is identifying and classifying by 57d39574-ee51-442c-bde1-7e8cc49548b2-2 00:44:51.895 --> 00:44:52.280 function. c9028c17-211a-4bb2-96bc-a4ecfbdfdeb4-0 00:44:55.160 --> 00:44:58.782 And equally important, if you have an HMI that runs on a c9028c17-211a-4bb2-96bc-a4ecfbdfdeb4-1 00:44:58.782 --> 00:45:02.785 recognized operating system like Windows and seems to meet all c9028c17-211a-4bb2-96bc-a4ecfbdfdeb4-2 00:45:02.785 --> 00:45:05.199 the prerequisites for an ADP machine. a305f9df-6e2d-4dd5-98d8-a8c505833a6f-0 00:45:06.200 --> 00:45:09.212 If the HMI is performing a principal function of electric a305f9df-6e2d-4dd5-98d8-a8c505833a6f-1 00:45:09.212 --> 00:45:12.485 control, then you're required to classify by that function and a305f9df-6e2d-4dd5-98d8-a8c505833a6f-2 00:45:12.485 --> 00:45:13.680 not as the ADP machine. abbcc8f9-0b0f-4409-ae94-677d731fe1bc-0 00:45:14.720 --> 00:45:16.560 This is a very common misconception. 21c587e0-4190-4f09-a162-64ee9d2da6c1-0 00:45:20.440 --> 00:45:24.753 So we don't have a lot of time, but if we want to answer any 21c587e0-4190-4f09-a162-64ee9d2da6c1-1 00:45:24.753 --> 00:45:27.440 questions, do you have any questions? 36e3ecc2-6019-4344-93e3-1328cb402257-0 00:45:27.440 --> 00:45:32.960 Right now there are no questions in the chat box yet. 5b408afb-0096-450c-bbb5-908056099882-0 00:45:34.880 --> 00:45:35.320 Awesome. 7ae56589-1c6e-4d30-a966-17516a798324-0 00:45:35.320 --> 00:45:35.960 Let's move on. cac53aa4-3253-431e-a8b0-91e843509945-0 00:45:42.120 --> 00:45:45.890 OK, so let's go over some examples of electrical control cac53aa4-3253-431e-a8b0-91e843509945-1 00:45:45.890 --> 00:45:49.000 machinery that are classified and had an 8537. d87007a3-df56-489a-b5a5-9e31a4e55e5f-0 00:45:50.280 --> 00:45:53.267 As we said earlier, we need to pay special attention to the d87007a3-df56-489a-b5a5-9e31a4e55e5f-1 00:45:53.267 --> 00:45:54.960 machines maximum voltage ratings. b23d44ea-18cf-4626-9dcc-8e9e446535dc-0 00:45:55.760 --> 00:45:59.959 Many medium and high voltage switch gear if you remember are b23d44ea-18cf-4626-9dcc-8e9e446535dc-1 00:45:59.959 --> 00:46:01.680 rated at over 1000 volts. ba41a30e-43ea-41c3-b7af-fe5e273e5c16-0 00:46:01.960 --> 00:46:04.401 So we need to keep in mind the operating voltages for ba41a30e-43ea-41c3-b7af-fe5e273e5c16-1 00:46:04.401 --> 00:46:05.080 classification. 2a8a4d9d-1a2c-4be3-8abb-2db8dff882ea-0 00:46:07.440 --> 00:46:11.872 When we have a switchboard or switch gear that is rated at 2a8a4d9d-1a2c-4be3-8abb-2db8dff882ea-1 00:46:11.872 --> 00:46:15.928 over 1000 volts, we're classifying down in subheading 2a8a4d9d-1a2c-4be3-8abb-2db8dff882ea-2 00:46:15.928 --> 00:46:19.760 853720, which I've highlighted here on the screen. 4f9e1179-741a-475a-977a-4b706947b91e-0 00:46:22.400 --> 00:46:25.858 Let's just say that this switch gear cabinet is rated at 1000 4f9e1179-741a-475a-977a-4b706947b91e-1 00:46:25.858 --> 00:46:26.640 volts or less. fa139f74-84ab-4c10-81d9-22857c93c7d3-0 00:46:27.360 --> 00:46:30.651 Inside we find power conducting components such as switches and fa139f74-84ab-4c10-81d9-22857c93c7d3-1 00:46:30.651 --> 00:46:32.040 circuit Breakers and fuses. f2c1ec7b-ce06-4740-8bb4-fd065318dddf-0 00:46:33.080 --> 00:46:34.280 There's Lightning investors. 0e39556e-77f5-4bb2-a996-03e7d26e4577-0 00:46:35.720 --> 00:46:39.480 All these conduct or interrupt the flow of electrical power. 631bfbb1-2223-491e-b543-354531754c84-0 00:46:41.400 --> 00:46:45.597 Like the MCC, switch gear can come in multiple sections with 631bfbb1-2223-491e-b543-354531754c84-1 00:46:45.597 --> 00:46:50.070 electrical control systems such as control panels, Transformers, 631bfbb1-2223-491e-b543-354531754c84-2 00:46:50.070 --> 00:46:54.543 protective relays and associated circuitry that monitor, control 631bfbb1-2223-491e-b543-354531754c84-3 00:46:54.543 --> 00:46:57.640 and protect the power conducting components. 63988b32-fa95-4ec7-8b80-52c5dd4e7f7c-0 00:46:59.760 --> 00:47:03.457 We would classify this switch your cabinet under head 63988b32-fa95-4ec7-8b80-52c5dd4e7f7c-1 00:47:03.457 --> 00:47:07.497 subheading 8537109120, which specifically calls for switch 63988b32-fa95-4ec7-8b80-52c5dd4e7f7c-2 00:47:07.497 --> 00:47:07.840 gear. 88da1328-0c77-4502-b63d-82858498d786-0 00:47:13.320 --> 00:47:16.447 In our next example, I'd like to talk about the classification of 88da1328-0c77-4502-b63d-82858498d786-1 00:47:16.447 --> 00:47:17.680 a programmable controller. da11619b-bf8e-45e2-9b16-02313b7bf3b6-0 00:47:17.680 --> 00:47:20.902 Again, remember that the programmable controllers da11619b-bf8e-45e2-9b16-02313b7bf3b6-1 00:47:20.902 --> 00:47:24.447 processor must meet certain conditions like the use of da11619b-bf8e-45e2-9b16-02313b7bf3b6-2 00:47:24.447 --> 00:47:28.701 programmable memory with storage of instructions for implementing da11619b-bf8e-45e2-9b16-02313b7bf3b6-3 00:47:28.701 --> 00:47:32.440 specific functions, whatever the explanatory nodes state. 08d25020-6512-4bd5-abe9-6e89898ea630-0 00:47:33.920 --> 00:47:37.480 But in my simulated real world, real world example here, the 08d25020-6512-4bd5-abe9-6e89898ea630-1 00:47:37.480 --> 00:47:40.516 reality is that we have individual modules that are 08d25020-6512-4bd5-abe9-6e89898ea630-2 00:47:40.516 --> 00:47:43.960 mounted and configured together to perform a control task. 1462be86-20d5-4e72-b844-be92ea64be41-0 00:47:44.840 --> 00:47:48.132 If we're really focusing on industrial controls, here's a 1462be86-20d5-4e72-b844-be92ea64be41-1 00:47:48.132 --> 00:47:51.255 prime example of how a programmable controller will be 1462be86-20d5-4e72-b844-be92ea64be41-2 00:47:51.255 --> 00:47:51.879 configured. b65bbc86-867b-4761-97b3-661f500eb277-0 00:47:52.840 --> 00:47:55.222 You can see that we have a processor module, and this is b65bbc86-867b-4761-97b3-661f500eb277-1 00:47:55.222 --> 00:47:56.560 what we would call the computer. 8f849b95-9f80-4c02-81f0-a6b937ffdc1f-0 00:47:58.160 --> 00:48:01.315 We also have a power supply module because obviously APLC 8f849b95-9f80-4c02-81f0-a6b937ffdc1f-1 00:48:01.315 --> 00:48:03.600 and its individual modules require power. 72c2dde2-dfdd-4cbb-a303-b3f07ae97a22-0 00:48:04.560 --> 00:48:07.132 And then we get into the various other types of modules that can 72c2dde2-dfdd-4cbb-a303-b3f07ae97a22-1 00:48:07.132 --> 00:48:08.360 be imported with the processor. 974e232e-1d93-4d8e-ae14-dcbcc6ceff6e-0 00:48:10.280 --> 00:48:13.908 A few slides ago we mentioned that output modules may be 974e232e-1d93-4d8e-ae14-dcbcc6ceff6e-1 00:48:13.908 --> 00:48:17.983 classified in subheading 853710 all on their own simply because 974e232e-1d93-4d8e-ae14-dcbcc6ceff6e-2 00:48:17.983 --> 00:48:21.484 they have powered outputs, whether it's relays or some 974e232e-1d93-4d8e-ae14-dcbcc6ceff6e-3 00:48:21.484 --> 00:48:25.177 other contact that would allow it to meet the two or more 974e232e-1d93-4d8e-ae14-dcbcc6ceff6e-4 00:48:25.177 --> 00:48:26.960 requirement of heading 8537. 551cfb8c-3b30-4c04-bc15-8b0378f2c79e-0 00:48:28.480 --> 00:48:31.849 But the input module may not be able to meet the heading 551cfb8c-3b30-4c04-bc15-8b0378f2c79e-1 00:48:31.849 --> 00:48:35.455 requirements, and we may have to classify it under the parts 551cfb8c-3b30-4c04-bc15-8b0378f2c79e-2 00:48:35.455 --> 00:48:36.520 provision of 8538. 04dc0771-1ab2-43f2-8fec-26d8249f6360-0 00:48:38.760 --> 00:48:41.420 These two classification issues have never been formally 04dc0771-1ab2-43f2-8fec-26d8249f6360-1 00:48:41.420 --> 00:48:42.680 addressed as far as I know. ab915988-7e37-4eff-8bf2-19a2ec40ab7e-0 00:48:43.920 --> 00:48:46.794 Again, in all instances you would need to identify the ab915988-7e37-4eff-8bf2-19a2ec40ab7e-1 00:48:46.794 --> 00:48:49.511 function of the module, determine how the module is ab915988-7e37-4eff-8bf2-19a2ec40ab7e-2 00:48:49.511 --> 00:48:52.594 constructed, and reference everything through note two and ab915988-7e37-4eff-8bf2-19a2ec40ab7e-3 00:48:52.594 --> 00:48:53.640 three to section 16. 94e037a2-9efc-466a-a65e-8d928602573e-0 00:48:59.870 --> 00:49:03.939 In these last few slides, I want to go over some hypothetical 94e037a2-9efc-466a-a65e-8d928602573e-1 00:49:03.939 --> 00:49:04.990 cabinet designs. 6725c81f-e362-4f1f-80f6-95c466c3ed62-0 00:49:06.590 --> 00:49:10.382 Here is a basic example of an electrical cabinet that contains 6725c81f-e362-4f1f-80f6-95c466c3ed62-1 00:49:10.382 --> 00:49:12.790 multiple circuit Breakers and switches. 969ed2ab-918f-48cc-86c7-26943161467b-0 00:49:14.030 --> 00:49:15.430 So what is this unit? 014d8577-2197-4d78-a56b-3adbb5d523eb-0 00:49:17.640 --> 00:49:22.755 It doesn't protect and control electric motors, so it's not an 014d8577-2197-4d78-a56b-3adbb5d523eb-1 00:49:22.755 --> 00:49:23.080 MCC. 9cec8f8b-018a-4923-aec9-9bae2dca7637-0 00:49:24.600 --> 00:49:27.563 It's not really a distribution panel based on its physical 9cec8f8b-018a-4923-aec9-9bae2dca7637-1 00:49:27.563 --> 00:49:28.920 characteristics and design. 7a562d3e-3cee-42a2-ba6a-f61ab0a218b4-0 00:49:30.240 --> 00:49:31.960 There are no programmable features here. f62218e9-b7b7-4349-a291-42a1df389443-0 00:49:31.960 --> 00:49:37.036 So D is out and E answer E can only be in play if all the f62218e9-b7b7-4349-a291-42a1df389443-1 00:49:37.036 --> 00:49:40.800 previous subheadings have been eliminated. e721c7b1-d48b-40e9-bb1f-e9761f7f5cda-0 00:49:41.440 --> 00:49:45.889 It obviously has two or more apparatus subheading 8536, and e721c7b1-d48b-40e9-bb1f-e9761f7f5cda-1 00:49:45.889 --> 00:49:48.040 it's mounted in or on a base. e34aaaa9-628d-4b9c-a6ce-6f7343764fac-0 00:49:48.560 --> 00:49:51.229 But the function of the switchboard is to distribute e34aaaa9-628d-4b9c-a6ce-6f7343764fac-1 00:49:51.229 --> 00:49:54.000 electrical power in buildings and industrial settings. e8295903-f156-46c7-aac3-177866b9393a-0 00:49:54.760 --> 00:49:55.840 So let's go with B. c0b14978-f4ac-474a-8b4e-d34be85e232d-0 00:50:04.650 --> 00:50:07.450 In this next example, we switched up a little bit. 5269f032-97b4-46a0-be9a-109915b8f529-0 00:50:07.850 --> 00:50:10.170 We'll introduce a programmable controller into the mix. fa09a0d6-5207-4533-83d6-63229caaa127-0 00:50:10.610 --> 00:50:13.339 Let's just say that this enclosure has a number of fa09a0d6-5207-4533-83d6-63229caaa127-1 00:50:13.339 --> 00:50:16.817 electrical switching and control apparatus and is installed in a fa09a0d6-5207-4533-83d6-63229caaa127-2 00:50:16.817 --> 00:50:18.690 microbrewery at the bottling line. c604ad67-f2b0-4954-a44e-da59abea2ef2-0 00:50:21.240 --> 00:50:23.240 Can we call this a motor Control Center? 03f18fb4-0360-4463-8f38-3f9be5431eaa-0 00:50:25.040 --> 00:50:28.525 No, the principal function here is not to control the operation 03f18fb4-0360-4463-8f38-3f9be5431eaa-1 00:50:28.525 --> 00:50:29.560 of electric motors. 8153e4d9-3a7e-4caf-b61f-32d6991c2150-0 00:50:30.680 --> 00:50:33.602 Remember, a motor Control Center consists of one or more 8153e4d9-3a7e-4caf-b61f-32d6991c2150-1 00:50:33.602 --> 00:50:36.627 enclosure enclosed sections having a common power bust and 8153e4d9-3a7e-4caf-b61f-32d6991c2150-2 00:50:36.627 --> 00:50:39.703 with each section containing motor starters, fuses, circuit 8153e4d9-3a7e-4caf-b61f-32d6991c2150-3 00:50:39.703 --> 00:50:41.599 Breakers and electrical disconnects. 6e725f7f-adfb-4115-817c-8b3e696938c9-0 00:50:42.360 --> 00:50:45.894 Yes, a motor Control Center can be a include a programmable 6e725f7f-adfb-4115-817c-8b3e696938c9-1 00:50:45.894 --> 00:50:49.428 controller along with push buttons and indicative light and 6e725f7f-adfb-4115-817c-8b3e696938c9-2 00:50:49.428 --> 00:50:50.960 variable frequency drives. 14efb1b4-402b-4749-ad5b-754437f7c438-0 00:50:51.960 --> 00:50:55.160 Function must be to principally control electric motors. ef7747ff-9dce-408f-9d0f-33377c10dbed-0 00:50:57.520 --> 00:50:59.640 How about answer BA switchboard? c98b3c45-91d7-4cab-b1e8-3cb801e839bc-0 00:51:01.280 --> 00:51:04.794 I think in this scenario we're starting to move away from the c98b3c45-91d7-4cab-b1e8-3cb801e839bc-1 00:51:04.794 --> 00:51:08.479 electrical distribution function that a switchboard provides and c98b3c45-91d7-4cab-b1e8-3cb801e839bc-2 00:51:08.479 --> 00:51:11.200 for that matter the distribution panel as well. 28561258-7d35-4146-95f6-6d599be5f21d-0 00:51:14.120 --> 00:51:18.325 In this scenario the cabinet takes on the identity of APLC 28561258-7d35-4146-95f6-6d599be5f21d-1 00:51:18.325 --> 00:51:22.460 because it's now a process controller and it's not just a 28561258-7d35-4146-95f6-6d599be5f21d-2 00:51:22.460 --> 00:51:25.240 switchboard that's distributing power. cf2b7b96-775a-4ed7-90f1-41a6aad72957-0 00:51:31.900 --> 00:51:36.456 And here in this example we have a multi section cabinet that has cf2b7b96-775a-4ed7-90f1-41a6aad72957-1 00:51:36.456 --> 00:51:40.185 motor starters, contractors, fuses, switches, circuit cf2b7b96-775a-4ed7-90f1-41a6aad72957-2 00:51:40.185 --> 00:51:42.740 Breakers and HMI and a power supply. 12b6f118-88a0-4600-a445-8f0bf8d4eada-0 00:51:45.400 --> 00:51:48.853 The physical characteristics of a of a distribution panel, if 12b6f118-88a0-4600-a445-8f0bf8d4eada-1 00:51:48.853 --> 00:51:52.251 you remember involve a wall mounted enclosure having various 12b6f118-88a0-4600-a445-8f0bf8d4eada-2 00:51:52.251 --> 00:51:55.704 circuit Breakers and switches that distribute electricity for 12b6f118-88a0-4600-a445-8f0bf8d4eada-3 00:51:55.704 --> 00:51:57.319 lights and building circuits. 82fb7855-dbbc-486f-ad6e-cd8c7d23533b-0 00:51:57.800 --> 00:52:02.214 This is directly from the NEMA NEMA definition, so I think we 82fb7855-dbbc-486f-ad6e-cd8c7d23533b-1 00:52:02.214 --> 00:52:04.280 can rule out the panel board. 26bc2004-449d-499a-b1ab-4b83264b28ea-0 00:52:06.480 --> 00:52:08.976 Since we do have switches and circuit Breakers, it would be 26bc2004-449d-499a-b1ab-4b83264b28ea-1 00:52:08.976 --> 00:52:11.180 hard to say that these cabinets are not distributing 26bc2004-449d-499a-b1ab-4b83264b28ea-2 00:52:11.180 --> 00:52:11.680 electricity. d2e60b5e-76f5-4cdb-8a99-3d87de81f40b-0 00:52:12.680 --> 00:52:17.132 But with the population of starters and contactors and d2e60b5e-76f5-4cdb-8a99-3d87de81f40b-1 00:52:17.132 --> 00:52:22.151 fuses that are present we know to be controlling exhaust fans d2e60b5e-76f5-4cdb-8a99-3d87de81f40b-2 00:52:22.151 --> 00:52:26.846 and pumps, I think we can say that it's not a switchboard d2e60b5e-76f5-4cdb-8a99-3d87de81f40b-3 00:52:26.846 --> 00:52:29.680 because it's doing something more. 6ad6eca9-7594-4af6-b759-ff33806d4f6d-0 00:52:33.040 --> 00:52:39.080 There is no PLC present, but we do have an HMI. 53f6785e-a416-4d75-bdca-ff9afc1b644c-0 00:52:39.640 --> 00:52:43.892 The HMI alone is classifiable under the other basket provision 53f6785e-a416-4d75-bdca-ff9afc1b644c-1 00:52:43.892 --> 00:52:45.040 for heading 8537. 748e7862-4c3a-4627-b34b-c1d9a7d88692-0 00:52:45.280 --> 00:52:49.477 It's doing some type of control and visual visualization for the 748e7862-4c3a-4627-b34b-c1d9a7d88692-1 00:52:49.477 --> 00:52:49.800 user. 5ad57f9f-883e-4d8c-ac3d-51c46a64f6c5-0 00:52:50.040 --> 00:52:53.735 But based on the other apparatus installed in this in these 5ad57f9f-883e-4d8c-ac3d-51c46a64f6c5-1 00:52:53.735 --> 00:52:57.368 sections, I think we have to say that it's a motor Control 5ad57f9f-883e-4d8c-ac3d-51c46a64f6c5-2 00:52:57.368 --> 00:52:57.800 Center. 8bdfa4ca-5480-48b6-ab09-c4db0aa49d68-0 00:52:59.400 --> 00:53:03.868 The existence of motor starters, contractors and other electrical 8bdfa4ca-5480-48b6-ab09-c4db0aa49d68-1 00:53:03.868 --> 00:53:07.998 protection apparatus that's there to control and protect and 8bdfa4ca-5480-48b6-ab09-c4db0aa49d68-2 00:53:07.998 --> 00:53:11.722 distribute power to electric motors makes this a clear 8bdfa4ca-5480-48b6-ab09-c4db0aa49d68-3 00:53:11.722 --> 00:53:15.175 candidate for the MCC classification in subheading 8bdfa4ca-5480-48b6-ab09-c4db0aa49d68-4 00:53:15.175 --> 00:53:15.920 8537106000. ee3f7c90-d2ba-4b83-acd8-d2f798506ecf-0 00:53:22.230 --> 00:53:25.282 And here in this example, we have a three section cabinet ee3f7c90-d2ba-4b83-acd8-d2f798506ecf-1 00:53:25.282 --> 00:53:28.230 that's populated with numerous speed drive controllers. 5f3f76bc-1157-4768-ad52-ec9970f51693-0 00:53:31.830 --> 00:53:34.957 If we have sections filled with drives and the drives function 5f3f76bc-1157-4768-ad52-ec9970f51693-1 00:53:34.957 --> 00:53:37.836 is to control the speed and direction of electric motors, 5f3f76bc-1157-4768-ad52-ec9970f51693-2 00:53:37.836 --> 00:53:40.120 isn't that considered a motor Control Center? bf76a84f-9657-4db0-8a36-90edafac646a-0 00:53:41.320 --> 00:53:44.560 Is a speed drive control the same thing as an MCC? a24c6e57-1610-4a68-9835-02db84ad4b5a-0 00:53:47.320 --> 00:53:52.240 No, a drive is not considered an MCCA. f029dcab-83ab-48dd-98ad-48310bf403bd-0 00:53:52.600 --> 00:53:52.880 Dr. e9b1bad0-5b1c-4140-9893-83ebfbc4133f-0 00:53:52.880 --> 00:53:56.823 is a static converting device that controls an AC motor speed e9b1bad0-5b1c-4140-9893-83ebfbc4133f-1 00:53:56.823 --> 00:54:00.640 and direction by varying the electrical supplies frequency. 7486f7f4-c391-45f4-a862-160e2c378cbf-0 00:54:02.000 --> 00:54:05.320 On the other hand, an MCC is an assembly of multiple enclosed 7486f7f4-c391-45f4-a862-160e2c378cbf-1 00:54:05.320 --> 00:54:08.426 sections containing control components used to manage and 7486f7f4-c391-45f4-a862-160e2c378cbf-2 00:54:08.426 --> 00:54:11.639 protect electric motors in industrial control applications. a1d41ecc-50b8-492f-9172-168b86eaf06f-0 00:54:13.000 --> 00:54:14.600 So this is not a motor Control Center. 56ef74b9-1282-4b37-bff1-523136c62dd4-0 00:54:17.560 --> 00:54:19.360 I think we can say it's not a switchboard. 035590f8-8f3d-45a3-b419-397233e3c1d0-0 00:54:20.360 --> 00:54:22.280 There's no programmable controller present. b56c7009-dd9b-4941-a60f-662f0b3fbc72-0 00:54:23.760 --> 00:54:27.307 But here's where it starts to get convoluted, because it's b56c7009-dd9b-4941-a60f-662f0b3fbc72-1 00:54:27.307 --> 00:54:30.675 highly likely that these cabinets will contain multiple b56c7009-dd9b-4941-a60f-662f0b3fbc72-2 00:54:30.675 --> 00:54:32.840 apparatus of heading 8535 and 8536. 8b56ffbe-4f4f-4b6d-917a-95a9790fa46b-0 00:54:34.240 --> 00:54:39.155 But if you fill a steel cabinet full of drives, is it anything 8b56ffbe-4f4f-4b6d-917a-95a9790fa46b-1 00:54:39.155 --> 00:54:40.560 more than a drive? 3d4413d0-e657-4165-bcd2-4aeba5e4059c-0 00:54:43.040 --> 00:54:47.041 In this scenario, I think we would classify this under 3d4413d0-e657-4165-bcd2-4aeba5e4059c-1 00:54:47.041 --> 00:54:50.680 subheading 85 or 440 as a speed drive controller. 5dc01b5b-5154-4dbb-8720-fa39b0d71300-0 00:54:51.640 --> 00:54:54.613 This is another scenario that I don't believe has ever been 5dc01b5b-5154-4dbb-8720-fa39b0d71300-1 00:54:54.613 --> 00:54:57.240 formally ruled upon, but it's good food for thought. b63ac261-4740-4f42-b684-9e8176716896-0 00:55:01.240 --> 00:55:04.737 Now in this last example, this sort of sums up the issue for us b63ac261-4740-4f42-b684-9e8176716896-1 00:55:04.737 --> 00:55:06.760 when we look at electrical cabinets. ce92ecd6-16bd-4668-a5ae-30b7f316ca88-0 00:55:07.560 --> 00:55:11.299 At some point we will come across the system that is put ce92ecd6-16bd-4668-a5ae-30b7f316ca88-1 00:55:11.299 --> 00:55:15.564 together to perform a number of industrial control functions and ce92ecd6-16bd-4668-a5ae-30b7f316ca88-2 00:55:15.564 --> 00:55:19.369 they will incorporate numerous named electrical apparatus ce92ecd6-16bd-4668-a5ae-30b7f316ca88-3 00:55:19.369 --> 00:55:23.240 configurations of heading 8537 like the switch or the MCC. 8783e8b5-ce28-4041-8bd2-f20bb81dcda5-0 00:55:25.320 --> 00:55:28.634 I believe complex configurations like this where you have 8783e8b5-ce28-4041-8bd2-f20bb81dcda5-1 00:55:28.634 --> 00:55:31.720 multiple components doing multiple functions are more 8783e8b5-ce28-4041-8bd2-f20bb81dcda5-2 00:55:31.720 --> 00:55:32.920 commonplace than not. 358401bb-8890-46cb-9db4-523e74d000d1-0 00:55:34.760 --> 00:55:37.794 As far as classification, you will have to look closely at 358401bb-8890-46cb-9db4-523e74d000d1-1 00:55:37.794 --> 00:55:40.880 what the principal function of the whole assembly is doing. c46ed86b-00e5-449a-ae33-6f20f4b390de-0 00:55:41.680 --> 00:55:44.710 This hypothetical configuration has the components that make up c46ed86b-00e5-449a-ae33-6f20f4b390de-1 00:55:44.710 --> 00:55:45.800 a motor Control Center. 1af5b05e-0ff5-43b6-925b-0dde92c6cff6-0 00:55:45.840 --> 00:55:50.241 For sure there are motor starters, contractors, etcetera 1af5b05e-0ff5-43b6-925b-0dde92c6cff6-1 00:55:50.241 --> 00:55:53.640 that's clearly controlling electric motors. 844cd955-f4ea-4d63-9de9-6fce939d9628-0 00:55:54.840 --> 00:55:57.646 Well, we also have this collection of drives which in 844cd955-f4ea-4d63-9de9-6fce939d9628-1 00:55:57.646 --> 00:56:00.661 themselves control electric motors, but the conversion of 844cd955-f4ea-4d63-9de9-6fce939d9628-2 00:56:00.661 --> 00:56:03.000 electricity that falls under heading 85 O 4. d272085c-08c9-43fa-83d9-46c2d95fc8c1-0 00:56:05.160 --> 00:56:08.857 We also have this collection of various switches and contactors d272085c-08c9-43fa-83d9-46c2d95fc8c1-1 00:56:08.857 --> 00:56:09.320 and HMI. 56f0c1b9-278b-4ef0-a764-7fdb129bf46a-0 00:56:09.720 --> 00:56:12.565 So it wouldn't be far off base to say this falls into the 56f0c1b9-278b-4ef0-a764-7fdb129bf46a-1 00:56:12.565 --> 00:56:13.400 basket provision. 2779f19c-c45f-4968-9bab-19421de1deac-0 00:56:16.400 --> 00:56:20.541 But I think here we have to look at the programmable controller 2779f19c-c45f-4968-9bab-19421de1deac-1 00:56:20.541 --> 00:56:24.423 because we enter in into a different level of functionality 2779f19c-c45f-4968-9bab-19421de1deac-2 00:56:24.423 --> 00:56:25.200 and purpose. 6a925cf1-a7dd-4470-9031-4a62f287648a-0 00:56:26.280 --> 00:56:29.772 Process control would likely take precedence over static 6a925cf1-a7dd-4470-9031-4a62f287648a-1 00:56:29.772 --> 00:56:33.388 conversion and the general control of the HMI and switches 6a925cf1-a7dd-4470-9031-4a62f287648a-2 00:56:33.388 --> 00:56:34.920 and the circuit Breakers. c54f42bd-f5d0-4a0f-a401-5686e9893b7b-0 00:56:36.400 --> 00:56:39.734 In this case, after gathering all the information about how c54f42bd-f5d0-4a0f-a401-5686e9893b7b-1 00:56:39.734 --> 00:56:43.347 the industrial control cabin is being used and after considering c54f42bd-f5d0-4a0f-a401-5686e9893b7b-2 00:56:43.347 --> 00:56:46.793 all its functions, I think we would say that the programmable c54f42bd-f5d0-4a0f-a401-5686e9893b7b-3 00:56:46.793 --> 00:56:50.406 controller takes precedence when determining the function of the c54f42bd-f5d0-4a0f-a401-5686e9893b7b-4 00:56:50.406 --> 00:56:51.240 whole assembly. f823759f-1221-4467-b588-dcb597aaee15-0 00:56:56.720 --> 00:57:00.280 So that wraps up this webinar on Industrial Controls. 5d3da10a-ec3b-453a-a955-9ef70bb213a8-0 00:57:00.440 --> 00:57:04.359 I realized it was a high level classification presentation, a 5d3da10a-ec3b-453a-a955-9ef70bb213a8-1 00:57:04.359 --> 00:57:08.215 little convoluted and requires the familiarity with multiple 5d3da10a-ec3b-453a-a955-9ef70bb213a8-2 00:57:08.215 --> 00:57:09.480 electrical headings. 1ed8bac1-c829-40e8-8039-6b0b1147b08c-0 00:57:10.720 --> 00:57:14.800 Remember, if you haven't viewed Industrial Controls Part 1, you 1ed8bac1-c829-40e8-8039-6b0b1147b08c-1 00:57:14.800 --> 00:57:16.840 can do that at this web address. caeaed18-30f3-4fd5-b648-7258f56fbefe-0 00:57:20.080 --> 00:57:23.400 And we classify machines in section 16 by function. 216a6405-f61e-4d37-a6dd-2fc161923db9-0 00:57:23.400 --> 00:57:24.520 I can't say that enough. f5241ccd-0cff-4a3f-8b17-eac69e574e96-0 00:57:25.400 --> 00:57:29.519 For a machine to be classified in HEAD 8537, it must conform to f5241ccd-0cff-4a3f-8b17-eac69e574e96-1 00:57:29.519 --> 00:57:31.000 all three requirements. d6e967c8-0a94-43c8-a3fb-dc4ae70a188c-0 00:57:31.000 --> 00:57:31.720 Remember that. 8b9f754b-64aa-4a31-b3f9-e18333bfc7d8-0 00:57:32.680 --> 00:57:34.120 And that's all we have for today. 21a5d21f-cbe9-4b26-b464-773a4a1b828d-0 00:57:34.480 --> 00:57:37.888 On the screen here you'll see the information for the CES 21a5d21f-cbe9-4b26-b464-773a4a1b828d-1 00:57:37.888 --> 00:57:41.591 credits and we have a couple of minutes to answer questions if 21a5d21f-cbe9-4b26-b464-773a4a1b828d-2 00:57:41.591 --> 00:57:42.120 you want. a5ca19d5-2b63-4512-a706-fab4ceef1f66-0 00:57:44.320 --> 00:57:46.720 OK, we have quite a few questions that came in. 4c7be138-628b-41c9-bc2d-eaf664ed26d9-0 00:57:47.720 --> 00:57:51.851 Let's see, first one, can you discuss exceptions such as 4c7be138-628b-41c9-bc2d-eaf664ed26d9-1 00:57:51.851 --> 00:57:56.490 heading 9022 for X-ray controls and 9032 for automatic electric 4c7be138-628b-41c9-bc2d-eaf664ed26d9-2 00:57:56.490 --> 00:57:57.360 controllers? a519cb31-90ac-4409-8505-024b72d8bf05-0 00:58:01.320 --> 00:58:06.604 Well, I would fall back to section 16 O3 you, you have to a519cb31-90ac-4409-8505-024b72d8bf05-1 00:58:06.604 --> 00:58:11.706 determine what the function of the article that's being a519cb31-90ac-4409-8505-024b72d8bf05-2 00:58:11.706 --> 00:58:12.799 imported is. b53dc926-ddd4-4e12-a914-3231635d4da3-0 00:58:13.240 --> 00:58:16.688 So if you have a cabinet that can, it can contain an article b53dc926-ddd4-4e12-a914-3231635d4da3-1 00:58:16.688 --> 00:58:19.120 of Chapter 90, an apparatus of Chapter 90. a79efe7c-a2b9-4522-8417-f82257525af9-0 00:58:20.040 --> 00:58:23.190 But the principal function of the cabinet must be either a79efe7c-a2b9-4522-8417-f82257525af9-1 00:58:23.190 --> 00:58:24.240 electrical control. 68f324fd-02d2-4c26-993c-bfe4a82d5b68-0 00:58:24.240 --> 00:58:27.736 And if it's not, then I suppose we could entertain going to 68f324fd-02d2-4c26-993c-bfe4a82d5b68-1 00:58:27.736 --> 00:58:28.960 Chapter 90 somewhere. 122796a4-bb2f-462e-a32e-4e9da373d2a3-0 00:58:29.200 --> 00:58:30.640 You have to involve the other. 31fc9b6d-02e6-42d6-8d57-53b367c14e2f-0 00:58:31.400 --> 00:58:32.160 And I asked for that. 79bb9027-08f7-4e19-acd1-6482da831d9f-0 00:58:32.160 --> 00:58:36.666 But these things they, you know, when you're importing cabinets 79bb9027-08f7-4e19-acd1-6482da831d9f-1 00:58:36.666 --> 00:58:40.890 and remember you have to meet the heading requirements, you 79bb9027-08f7-4e19-acd1-6482da831d9f-2 00:58:40.890 --> 00:58:44.692 have to have three or more aparast of of 8535 or 8536 79bb9027-08f7-4e19-acd1-6482da831d9f-3 00:58:44.692 --> 00:58:45.959 mounted on a base. a33a4444-8b32-4c1a-8e71-fc6bc54341da-0 00:58:45.960 --> 00:58:48.280 So you're already talking about a cabinet of some kind. db454fe2-3230-49ea-af05-e97e449700fd-0 00:58:49.040 --> 00:58:52.387 The presence of something from Chapter 90 in there wouldn't db454fe2-3230-49ea-af05-e97e449700fd-1 00:58:52.387 --> 00:58:55.400 necessarily disqualify from being classified in 8537. 2ba6c254-1868-47e8-99ab-0d78348c9c53-0 00:58:57.680 --> 00:58:58.880 I hope that answers your question. dd61ec97-9163-423e-bdf7-e58db32bfd90-0 00:59:00.400 --> 00:59:00.520 OK. 1227eca1-8243-4808-a9ee-197968297b2d-0 00:59:00.600 --> 00:59:04.337 The next question, to qualify for 8537, do the two parts of 1227eca1-8243-4808-a9ee-197968297b2d-1 00:59:04.337 --> 00:59:08.448 8536 need to be different or can you have two of the same type of 1227eca1-8243-4808-a9ee-197968297b2d-2 00:59:08.448 --> 00:59:08.760 item? fc488282-3c0a-483a-b720-bac87ee5fcc4-0 00:59:10.120 --> 00:59:11.520 I don't believe they need to be different. 951f0b7c-ab0c-4b70-9a7c-0f5414f7c202-0 00:59:11.520 --> 00:59:17.955 I think this was addressed at some point in in an older 951f0b7c-ab0c-4b70-9a7c-0f5414f7c202-1 00:59:17.955 --> 00:59:18.760 ruling. 730ef75a-2934-4dc0-b11b-a8b6b17cbc5d-0 00:59:19.800 --> 00:59:20.440 It doesn't. 4921d86a-3632-49ff-b2b2-a0aa775ecbc6-0 00:59:20.760 --> 00:59:26.360 It doesn't need to be different types of of of apparatus. 019b1f9f-5ebb-4a2c-8fc7-58d524b19bbc-0 00:59:26.360 --> 00:59:30.745 In other words, you can have two push button switches attached to 019b1f9f-5ebb-4a2c-8fc7-58d524b19bbc-1 00:59:30.745 --> 00:59:34.864 a panel, A metal panel and and that would, that would satisfy 019b1f9f-5ebb-4a2c-8fc7-58d524b19bbc-2 00:59:34.864 --> 00:59:38.320 you have two or more switches, individual switches. 54476fd9-d523-4ffa-93eb-c9e758abba6a-0 00:59:39.160 --> 00:59:43.508 We already get into some weird stuff is when you have an 54476fd9-d523-4ffa-93eb-c9e758abba6a-1 00:59:43.508 --> 00:59:48.161 assembly, it's it's an all in one assembly that has multiple 54476fd9-d523-4ffa-93eb-c9e758abba6a-2 00:59:48.161 --> 00:59:49.840 switches inside of it. f04aafd9-d17d-45f4-b380-00eedf9ff2bd-0 00:59:51.360 --> 00:59:52.720 That may only count as one. 511e8229-e62a-4983-8417-000f260c76cd-0 00:59:52.960 --> 00:59:55.360 So it'd have to be looked at on a case by case basis. 08b03082-40d2-4644-b451-03aa25653cc0-0 00:59:55.360 --> 00:59:58.992 But the answer to the question is no, they do not have to be 08b03082-40d2-4644-b451-03aa25653cc0-1 00:59:58.992 --> 01:00:00.600 the same type of apparatus. 6ca860d4-b9d7-4b5d-a1dc-dea8a80df582-0 01:00:02.680 --> 01:00:02.840 OK. d0b715ea-b8b0-4c47-9bf8-31162f137912-0 01:00:03.640 --> 01:00:06.600 Do you have another example of a switch gear and switchboard? acd0b00c-65a9-4163-a9c3-99a950865310-0 01:00:10.200 --> 01:00:11.320 Not off the top of my head. a892a1c9-7dc6-4630-89d7-9606f98814e1-0 01:00:12.000 --> 01:00:16.521 If you go do a search and cross there might there's a couple of a892a1c9-7dc6-4630-89d7-9606f98814e1-1 01:00:16.521 --> 01:00:20.760 older rulings that to have it switch gear and switchboards. 2821633b-b879-4084-a850-1a36bc88ffd5-0 01:00:22.080 --> 01:00:24.200 I don't see much of them to be honest. 3d6d9ee2-6d73-4541-9611-54e9d817d235-0 01:00:25.160 --> 01:00:28.640 They're specifically provided for in the tariff, so. 6ce492a0-43aa-4e85-97f9-59411d18e3ae-0 01:00:30.440 --> 01:00:34.080 It seems like it would be a pretty easy identification. 180c908f-528d-4c72-85f2-75ec3f1f3b3a-0 01:00:35.200 --> 01:00:38.466 I think when when you're getting into the switch gear 180c908f-528d-4c72-85f2-75ec3f1f3b3a-1 01:00:38.466 --> 01:00:42.398 switchboards, you're looking at the function of the of the panel 180c908f-528d-4c72-85f2-75ec3f1f3b3a-2 01:00:42.398 --> 01:00:46.270 of the cabinet, what it's doing, how it's configured, obviously 180c908f-528d-4c72-85f2-75ec3f1f3b3a-3 01:00:46.270 --> 01:00:47.480 what's inside of it. 83508112-9e55-4a7f-be00-3b7293820065-0 01:00:48.000 --> 01:00:51.956 And and then that was sort of forced you into that switchboard 83508112-9e55-4a7f-be00-3b7293820065-1 01:00:51.956 --> 01:00:53.840 or switch gear classification. 148dac79-25ed-4245-b0a8-3b1fda52bdbd-0 01:00:57.120 --> 01:01:00.734 OK, What if one of the modules, slide 41, for example, a power 148dac79-25ed-4245-b0a8-3b1fda52bdbd-1 01:01:00.734 --> 01:01:04.292 supply is imported separately, will it still be classified by 148dac79-25ed-4245-b0a8-3b1fda52bdbd-2 01:01:04.292 --> 01:01:05.440 function or by name? 4c03143b-25db-4f31-9e99-1bd6c5790d0c-0 01:01:06.160 --> 01:01:09.400 Everything classified in Section 16 is classified by function. b212db54-f815-4086-9b3d-47f611733a82-0 01:01:10.520 --> 01:01:14.538 If a power supply module comes in by itself, it's classified as b212db54-f815-4086-9b3d-47f611733a82-1 01:01:14.538 --> 01:01:15.480 a power supply. b4c6f09b-d7fa-483a-9f13-629be30ddf4e-0 01:01:16.240 --> 01:01:20.739 If the power supply module comes in attached or part of an entire b4c6f09b-d7fa-483a-9f13-629be30ddf4e-1 01:01:20.739 --> 01:01:24.897 programmable controller system, in other words, you have the b4c6f09b-d7fa-483a-9f13-629be30ddf4e-2 01:01:24.897 --> 01:01:29.055 power supply, the CPU input modules, the output modules, and b4c6f09b-d7fa-483a-9f13-629be30ddf4e-3 01:01:29.055 --> 01:01:32.600 so forth, it would all be classified as the system. 82f3e219-4bdf-4431-9a3e-4d6813f160c7-0 01:01:32.960 --> 01:01:33.840 As the PLC. 01d1e83e-ad0b-4732-a543-0a82ceb96778-0 01:01:34.520 --> 01:01:38.310 You wouldn't break the power supply out, but if it's coming 01d1e83e-ad0b-4732-a543-0a82ceb96778-1 01:01:38.310 --> 01:01:41.280 in by itself, you always classify by function. f866007e-8eed-41fc-b4b6-670b83bc59ce-0 01:01:43.360 --> 01:01:44.440 So it'd be 85 O 4. 13b13c82-018f-4120-8bdf-0bd8973c1d73-0 01:01:48.120 --> 01:01:49.360 And then you had a couple questions. ee7f9b28-8e23-4d79-b6e0-e3ceedf44f87-0 01:01:49.400 --> 01:01:51.520 Sorry, what was the HTS for the drive? d6581bc3-0738-49c0-86fa-ac9020d2de8d-0 01:01:51.520 --> 01:01:53.867 And then someone asked if you could repeat the classification d6581bc3-0738-49c0-86fa-ac9020d2de8d-1 01:01:53.867 --> 01:01:54.360 of the drive. e2cc0f52-947c-439f-9d3b-612c199ad92d-0 01:01:54.360 --> 01:01:55.800 I think it's slide 45. e0c7a4f4-627e-484b-b227-d042c129fbc2-0 01:01:56.920 --> 01:02:02.903 Drives are classifiable under subheading 85 O 440 speed drive e0c7a4f4-627e-484b-b227-d042c129fbc2-1 01:02:02.903 --> 01:02:07.440 controllers and that's a whole nother webinar. d15d0bf4-8ff4-4229-9437-65baa9ab8fac-0 01:02:10.000 --> 01:02:15.369 Basically they control the speed and direction of electric motors d15d0bf4-8ff4-4229-9437-65baa9ab8fac-1 01:02:15.369 --> 01:02:19.600 by converting the electrical frequency and current. 98ba8716-ccc4-4983-94c2-418470c0f546-0 01:02:20.840 --> 01:02:22.400 It's a static conversion process. 911a8416-7d81-4000-838c-124fc6aad4e0-0 01:02:25.640 --> 01:02:27.880 OK, what about the census warning? 566b7e5e-c2b7-4c23-bf2c-859927bd774f-0 01:02:27.880 --> 01:02:31.590 If you consider this one unit quantity 1 high value, do you 566b7e5e-c2b7-4c23-bf2c-859927bd774f-1 01:02:31.590 --> 01:02:35.240 divide into the 12 drives drives shown to establish value? e9a009b0-e7f8-428f-832e-426e150b66e5-0 01:02:39.720 --> 01:02:40.360 No idea. edee8a6a-1397-4643-9aaa-70ba04ee62fc-0 01:02:41.520 --> 01:02:44.880 Send me an e-mail, My email's on the screen. 935b6246-ed11-40fe-aca5-ffa32cb1f828-0 01:02:47.000 --> 01:02:47.400 That's. d73fab87-56ec-487f-9e7e-c70702da9353-0 01:02:47.400 --> 01:02:49.680 Yeah, I don't know. b96fefab-b65b-4f33-87fd-c5e3c2e3da03-0 01:02:49.680 --> 01:02:50.640 Not off top, Top my head. 5cc95386-b795-46db-aa07-cf60c73697ff-0 01:02:50.640 --> 01:02:51.080 I don't know. d33358ee-042f-4cbd-8977-54c232ec9d28-0 01:02:51.840 --> 01:02:51.960 OK. bd5ea180-5447-4eea-b632-6ac31c6d2b54-0 01:02:52.040 --> 01:02:54.520 And then there's one more question, as far as I can tell. 5d350916-1e93-4ca6-9311-e0c3f1f2ee25-0 01:02:54.520 --> 01:03:00.160 Is there a webinar on 85268526? 0e0eed6b-dd72-4db1-8f07-02706f3f1ed8-0 01:03:00.640 --> 01:03:02.560 Would be what radar? b5079317-1e5c-4873-910a-cd8c437b7f71-0 01:03:04.720 --> 01:03:05.280 I don't know. be6f59df-fc99-4595-ac21-797cbb449b66-0 01:03:05.800 --> 01:03:09.040 I think that would be handled by NIS Lisa Cariello. 40e2950d-213c-44a0-88c3-20f543dfcbf2-0 01:03:14.320 --> 01:03:16.840 She might have just done one recently on that. 28897267-48a2-4a87-8771-34058ab1e85e-0 01:03:16.840 --> 01:03:21.330 So yeah, I would go up to if you look at the top bullet here, it, 28897267-48a2-4a87-8771-34058ab1e85e-1 01:03:21.330 --> 01:03:24.800 it gives you the web address for all the webinars. ab56add4-85b3-4c40-b5ae-bf0abede888f-0 01:03:25.160 --> 01:03:29.445 And if it's a current webinar that's been conducted and ready ab56add4-85b3-4c40-b5ae-bf0abede888f-1 01:03:29.445 --> 01:03:33.454 for publication, it will be listed up in that on that web ab56add4-85b3-4c40-b5ae-bf0abede888f-2 01:03:33.454 --> 01:03:33.800 page. 831ac750-8b42-46c5-b4ef-031a9cc65d8a-0 01:03:36.400 --> 01:03:36.600 OK. 869948e5-f382-4560-a509-bdbec466e0c9-0 01:03:36.600 --> 01:03:41.328 And then finally, is there a webinar on 8537 versus 8538, in 869948e5-f382-4560-a509-bdbec466e0c9-1 01:03:41.328 --> 01:03:45.592 particular PCBA, maybe industrial controls part three, 869948e5-f382-4560-a509-bdbec466e0c9-2 01:03:45.592 --> 01:03:46.600 I don't know. 53b6e373-930a-4715-8d1a-bb4a3197feed-0 01:03:49.600 --> 01:03:50.880 We might make a run at this. cee08577-3700-4b82-8986-70cdb88dc021-0 01:03:51.040 --> 01:03:51.400 I don't know. 2a9a16a2-95b1-4d3c-916d-312045ca7e3b-0 01:03:51.400 --> 01:03:52.160 We'll see. 592c57c4-f47f-48d4-9659-f9faf5242bd6-0 01:03:55.040 --> 01:03:56.040 OK, that's all you got. a33443ac-a1b9-4a74-b654-3efd1cf3c3cb-0 01:03:56.480 --> 01:03:57.920 OK, Well, thank you everybody. 8a7508bf-83a3-467a-b52a-6404415a7c29-0 01:03:57.920 --> 01:03:59.120 I appreciate your time. f05234f7-df24-4b38-a1b8-8848f2475962-0 01:04:00.120 --> 01:04:01.560 Have a good rest of your week. 5a84a851-5fd4-489e-945f-297c2be69d0e-0 01:04:11.920 --> 01:04:14.200 This concludes our webinar for this afternoon. 0d60a906-ea99-43f3-9409-9b380c558e64-0 01:04:14.600 --> 01:04:17.990 This is a reminder that this webinar will be posted on the 0d60a906-ea99-43f3-9409-9b380c558e64-1 01:04:17.990 --> 01:04:18.680 CBP website. fbc98faa-161b-42dc-8a60-ce71c67dc9cc-0 01:04:19.120 --> 01:04:21.840 Thank you for joining us and enjoy the rest of your day.